Table 6 Performance summary of the proposed fuzzy-PS MPPT controller: ideal versus achieved power and calculated tracking efficiency for all simulated irradiance and temperature cases.

From: Fuzzy controller-driven pattern search optimization for a DC–DC boost converter to enhance photovoltaic MPPT performance

Scenario

Condition

Achieved power (kW)

Ideal power (kW)

MPPT efficiency (%)

Irradiance change

1000 W/m²

74.48

74.48

100%

500 W/m²

37.24

37.24

100%

1400 W/m²

104.27

104.27

100%

1600 W/m²

90

119.17

75.5%

1200 W/m²

83

89.38

92.8%

Temperature change

25 °C

74.48

74.48

100%

45 °C

67

74.48

90%

10 °C

83

74.48

111.4%

30 °C

72.50

74.48

97.3%

40 °C

70

74.48

94%

Overall

All cases

796.14

756.97