Table 6 Energy distribution in the furnace and the coil (kW).
Furnace | Cracking process | Conventional De-Coke process | Burning Coke De-Coke process |
---|---|---|---|
\(\:{En}_{in}\) (kW) | 51164.41 | 14493.04 | 15711.66 |
\(\:{En}_{coil}\) (kW) | 22944.10 | 2171.10 | 2159.08 |
\(\:{En}_{cv}\) (kW) | 830.16 | 1622.27 | 5595.61 |
\(\:{En}_{ex}\) (kW) | 27390.16 | 10699.66 | 7956.98 |
Coil | |||
\(\:{En}_{in}\) (kW) | 339577.78 | 8672.31 | 8672.31 |
\(\:{En}_{cv}\) (kW) | 22944.10 | 7555.69 | 7555.69 |
\(\:{En}_{ex}\) (kW) | 316633.68 | 1116.62 | 1116.62 |