Table 1 Benchmarking ranges of parameters for various fault Types.

From: Effectiveness of supervised machine learning models for electrical fault detection in solar PV systems

Sl.No

Fault type

Power min

Power max

Voltage Min

Voltage max

Current min

Current max

Temp min

Temp max

1

GF

64.96

95.76

84.12

111.94

0.69

1.44

25

34

2

MF

75.83

104.68

351

410.98

0.17

0.32

25

34

3

Normal

83.79

119.26

373.03

426.32

0.2

0.3

25

34

4

OC

0

0

370.6

431.93

0

0

25

34

5

SC

0

0

0

0

0.75

1.41

25

34