Table 4 RF parameters of the HHC.
Parameter | Superfish | CST studio suite (with ports) | CST studio suite (without ports) |
---|---|---|---|
Frequency (MHz) | 301.23 | 300.15 | 299.77 |
Shunt impedance (MΩ) | 6.93 | 6.92 | 6.95 |
Quality factor | 23,210 | 23,000 | 23,100 |
Parameter | Superfish | CST studio suite (with ports) | CST studio suite (without ports) |
---|---|---|---|
Frequency (MHz) | 301.23 | 300.15 | 299.77 |
Shunt impedance (MΩ) | 6.93 | 6.92 | 6.95 |
Quality factor | 23,210 | 23,000 | 23,100 |