Table 10 The main physical properties of compacted CFA.
Simulative ash column | Compacted thickness(cm) | Dry Density (g/cm3) | Compaction Coefficient | Hydraulic Conductivity (cm/s) |
---|---|---|---|---|
No.1 | 13.1 | 0.454 | 0.431 | 4.874 × 10− 4 |
No.2 | 10.5 | 0.566 | 0.537 | 1.218 × 10− 4 |
No.3 | 9 | 0.661 | 0.627 | 5.331 × 10− 5 |
No.4 | 7.5 | 0.793 | 0.752 | 2.285 × 10− 5 |
No.5 | 5.9 | 1.008 | 0.956 | 1.523 × 10− 5 |