Table 5 Numerical results of test 1 (variable WS profile).
From: Controlling the energies of the single-rotor large wind turbine system using a new controller
Ps (W) | Qs (VAR) | ||
---|---|---|---|
PI controller | Overshoot | 05 | 14.42 |
Fluctuations | 47 | 52.40 | |
RT (ms) | 0.103 | 0.105 | |
SSE | 17 | 23.94 | |
Proposed controller | Overshoot | 50 | 196.70 |
Fluctuations | 18 | 22.60 | |
RT (ms) | 0.100 | 0.264 | |
SSE | 3.6 | 10 | |
Improvement Ratios (%) | Overshoot | -81.82 | -92.67 |
Fluctuations | 61.70 | 56.87 | |
RT (ms) | 2.91 | -60.23 | |
SSE | 78.82 | 58.23 |