Table 2 Mix proportions of foamed concrete.

From: Uncovering the influence of gold tailings on foam stability and mechanical performances of foamed concrete

Mix

Target density (kg/m3)

OP (kg)

GBFS (kg)

GT (kg)

Water (kg)

CaOH (%)

Actual foam (m3)

Dry density (kg/m3)

FC-REF

600

75

299

-

187

5

0.9

626 ± 3

FC-GT-5%

600

75

261.6

37.4

187

5

0.9

623 ± 5

FC-GT-10%

600

75

224.2

74.8

187

5

0.9

617 ± 4

FC-GT-20%

600

75

186.8

112.2

187

5

0.9

612 ± 4