Table 1 Dimensional Ratios for Hydrocyclone Design: Optimized Proportions for Enhanced Separation Efficiency.

From: Numerical simulation and experimental study of suspended particulate matter removal for efficient water recovery and reuse in solid–liquid separation

Ratios

Di/D

De/D

H/D

h/D

S/D

B/D

Li/D

Le/D

Current model

0.212

0.2125

2.2083

0.625

0.5

0.212

0.833

0.416