Table 9 ANOVA analysis and model validation for recycled aggregate concrete with fibers.

From: Performance analysis of fiber reinforced recycled aggregate concrete at elevated temperatures using response surface methodology

Responses

Compressive strength

Tensile strength

Elastic modulus

Psi

Psi

Psi

Standard deviation

162.84

75.88

61,425.23

Mean R2

0.9478

0.9302

0.9452

Predicted R2

0.9354

0.9135

0.9321

Adjusted R2

0.9174

0.8889

0.9108

Adequate precision

22.5719

20.7510

27.8076

F-value (model)

76.25

55.95

72.41

p-value (model)

< 0.0001

< 0.0001

< 0.0001

Model

Significant

Significant

Significant

Lack of fit (F and p values)

Not significant (F value = 10.05 p value = 0.0004)

Not significant (F value = 5.75 p value = 0.0061)

Not significant (F value = 7197.11 p value ≤ 0.0001)

Final model type

Quadratic

2FI