Fig. 7
From: Reduced listening effort with adaptive binaural beamforming in realistic noisy environments

(a) Alpha power differences between Q-Omni and DM at SRT-80 (left) and SRT-95 (right) represented in terms of t-statistics. Crosses indicate EEG channels that form clusters with statistically significant absolute differences between the two hearing aid programs. (b) Averaged power spectrum across participants and EEG channels within each cluster for the two evaluated SRTs at the [\(-1.0\) – 0.0] s and [2.0 – 3.5] s time intervals. The alpha frequency band is highlighted with a grey background.