Table 5 The control parameters of the proposed optimization techniques and operative restrictions.
From: A comprehensive study of recent maximum power point tracking techniques for photovoltaic systems
Algorithm | Parameters | Value |
---|---|---|
PWM with PI controller | \(\:{V}_{ref}^{finite}\) | 34.04 |
\(\:{V}_{ref}^{max}\) | 43.2 | |
\(\:{V}_{ref}^{min}\) | 0 | |
\(\:\varDelta\:{V}_{ref}\) | 0.0001 | |
\(\:{K}_{p}\) | 0.001 | |
\(\:{K}_{i}\) | 0.01 | |
P&O | \(\:{D}_{finite}\) | 0.8234 |
\(\:{D}_{max}\) | 0.95 | |
INC | \(\:{D}_{min}\) | 0.1 |
\(\:\varDelta\:D\) | 0.0001 | |
PSO | \(\:{c}_{1}\) | 1.05 |
\(\:{c}_{2}\) | 1.05 | |
\(\:W\) | 0.8 | |
\(\:{N}_{P}\) | 4 | |
ANN | neurons in \(\:{L}_{i}\) | 2 |
neurons in \(\:{L}_{o}\) | 1 | |
Neurons in \(\:{L}_{h}\) | 10 | |
Training | 1000 | |
FLC | Input 1 (\(\:E\)) | 7 MF |
Input 2 (\(\:\varDelta\:E\)) | 7 MF | |
Output (\(\:\varDelta\:D\)) | 7 MF | |
Rules | 49 |