Table 1 Repeatability, Intermediate precision and Format Variability data for hMPV-A1 and hMPV-B1. Values expressed in percentage indicate GCV. Acceptability criteria: GCV ≤ 65.5% for Repeatability; GCV ≤ 129.0% for Intermediate precision; GCV ≤ 81.5% for Format Variability. The assay meets all criteria for both strains. GCV: geometric coefficient of variation; GMT: geometric mean titer.

From: Design and validation of a semi-quantitative microneutralization assay for human Metapneumovirus A1 and B1 subtypes

hMPV-A1

Fold dilution

Observed GMT

Repeatability (%)

Fold dilution

Observed GMT

Intermediate precision (%)

Fold dilution

Observed

GMT

Format variability (%)

1

640

0.0%

1

640

0.0%

1

640

0.0%

2

302

22.2%

2

302

22.2%

2

302

15.2%

4

107

41.4%

4

107

43.2%

4

107

28.9%

8

63

39.8%

8

63

41.4%

8

63

27.8%

16

38

22.2%

16

38

22.2%

16

38

15.2%

32

19

22.2%

32

19

22.2%

32

19

15.2%

64

10

0.0%

64

10

0.0%

64

10

0.0%

hMPV-B1

Fold dilution

Observed

GMT

Repeatability (%)

Fold dilution

Observed

GMT

Intermediate precision (%)

Fold dilution

Observed

GMT

Format variability (%)

1

718

22.2%

1

718

56.4%

1

718

37.2%

2

339

22.2%

2

339

22.2%

2

339

15.2%

4

170

22.2%

4

170

22.2%

4

170

15.2%

8

85

41.4%

8

85

43.2%

8

85

28.9%

16

42

22.2%

16

42

22.2%

16

42

15.2%

32

21

32.7%

32

21

46.7%

32

21

31.1%

64

13

22.2%

64

13

46.7%

64

13

31.1%