Table 1 Overview of the study dataset showing more than 118,000 days of CGM data with over 2.2 million blood glucose samples from 108 young adults with type 1 diabetes. \(\phantom{0}^*\)Hemoglobin A1 C values collected via the mail-in AccuBase A1c test kit.

From: Seasonal, weekly, and individual variations in long-term use of wearable medical devices for diabetes management

 

Attributes

Mean ± SD

Range

Not Available

Demographics

Total no. of participants

108

\(\backslash\)

\(\backslash\)

Age (yrs.)

23 ± 3

19 - 29

\(\backslash\)

Male/Female

26/78

\(\backslash\)

4

White/Black/Others

77/12/7

\(\backslash\)

12

Time since T1D diagnosis (yrs.)

11.5 ± 5.3

2.4 - 27.0

2

Hemoglobin A1C (%)\(\phantom{0}^*\)

8.4 ± 1.3

6.3 - 14.4

14

Insulin pump/Multiple daily injections

88/20

\(\backslash\)

\(\backslash\)

Private/Public insurance

78/18

\(\backslash\)

12

CGM use

Device (Dexcom/Medtronic)

103/1

\(\backslash\)

4

Total duration of data (days)

118325

\(\backslash\)

\(\backslash\)

Duration of data/participant (days)

1096 ± 580

272 - 2412

\(\backslash\)

Total days with no CGM use

32931

\(\backslash\)

\(\backslash\)

Total days with high CGM use

76435

\(\backslash\)

\(\backslash\)

Blood glucose data

Total BG samples

22,985,747

\(\backslash\)

\(\backslash\)

Number of BG samples/participant

212,831 ± 139,929

7,721 - 601,407

\(\backslash\)

Mean blood glucose/day (mg/dL)

195.2 ± 49.2

70.4 - 401.0

\(\backslash\)

Mean time in range/day (%)

47.0 ± 24.1

0 - 100

\(\backslash\)