Table 1 Boundary layer parameters for the lumen (wall) and stent. Lengths and thicknesses are in mm.

From: Influence of boundary conditions and blood rheology on indices of wall shear stress from IVUS-based patient-specific stented coronary artery simulations

Surface

Surface edge length

First layer thickness

Total BL thickness

Number of layers

Lumen

0.045

0.055

0.500

4

Stent

0.020

0.010

0.045

3