Table 1 Summary of stimulus parameters for perceptual attributes.

From: Investigating perceptual discrimination thresholds for attributes of whole-body vibration

Attribute

Stimulus Type

Frequency Range (Hz)

Amplitude Range (dB SL)

Additional Parameters

Reference Stimuli

Test Stimuli

Weak

Sinusoidal

50

10–30

-

26 dB

30, 28, 24, 22 dB

18 dB

20, 16 dB

14 dB

12, 10 dB

Up-and-Down

Sinusoidal

12–100

20

-

17 Hz

12, 20, 22 Hz

30 Hz

25, 35 Hz

55 Hz

45, 65, 75, 100 Hz

Tingling

Sinusoidal

100–300

25

-

120 Hz

100, 110, 130, 140 Hz

225 Hz

200, 250, 275, 300 Hz

Repetitive

Amp. Modulated

50 (carrier)

25

Modulation Freq.: 2–10 Hz

2.4 Hz

2, 2.2, 2.8 Hz

3.6 Hz

2.8, 3.9 Hz

5 Hz

2.5, 7.5, 10 Hz

Even

Narrowband Noise

50 (center)

25

Bandwidth: 0–25 Hz

3 Hz

0, 1, 2, 4, 5, 6 Hz

10 Hz

8, 15, 20, 25 Hz

Fading

Impulse

5

Varying

Decay Rate (\(\delta\)): 0.5–4.5

\(\delta = 0.5\)

\(\delta = 1\)

\(\delta = 2\)

\(\delta = 1.5, 2.5\)

\(\delta = 4\)

\(\delta = 2.5, 3, 3.5, 4.5\)