Table 1 Differential effects of sex on the supraventricular electrophysiology and atrial arrhythmic susceptibility of unanesthetized rats

From: Differential effects of anesthetics and sex on supraventricular electrophysiology and atrial fibrillation substrate in rats

Parameter

Male (n = 13)

Female (n = 16)

P value

Animal weight (g)

386.5 ± 6.7

278.0 ± 5.3

<0.001***

RR interval (ms)

182.2 ± 4.21

168.6 ± 3.48

0.019*

PR interval (ms)

49.96 ± 1.15

46.99 ± 0.9

0.049*

CSNRT (ms)

20.29 ± 1.87

23.15 ± 1.69

0.267

AERP 70 CL (ms)

26.22 ± 1.45

31.56 ± 1.43

0.019*

AERP 100 CL (ms)

27.33 ± 1.48

31.10 ± 1.54

0.098

AERP 120 CL (ms)

26.11 ± 1.26

30.40 ± 1.59

0.053

AVERP 100 CL (ms)

75.08 ± 0.97

73.75 ± 1.67

0.534

AVERP 110 CL (ms)

73.31 ± 0.92

72.75 ± 1.78

0.797

AVERP 120 CL (ms)

73.38 ± 1.06

72.25 ± 1.73

0.602

AVERP 130 CL (ms)

71.92 ± 1.14

71.25 ± 1.57

0.742

AV 2:1 block (ms)

75.83 ± 1.72

70 ± 1.49

0.021*

AV Wenckebach block (ms)

90.83 ± 2.03

82.5 ± 1.34

0.004**

Regular SVT induction (%)

12.31 ± 2.69

10.63 ± 3.22

0.420

Regular SVT duration (s)

236.98 ± 140.37

125.55 ± 105.04

0.177

AF induction (%)

30.77 ± 6.72

9.69 ± 3.04

0.010*

AF duration (s)

48.57 ± 28.83

5.54 ± 1.89

0.016*

Mean CR

1.22 ± 0.03

1.1 ± 0.02

0.009**

Arrhythmic CR (%)

39.34 ± 5.83

16.81 ± 4.30

0.009**

  1. Comparison between the supraventricular electrophysiological parameters of male and female rats obtained in the UAS 4 weeks after right-atrial quadripolar electrode implantation. Note the reduced AERP and markedly increased AF susceptibility in males compared with females. Mean CR refers to the average CR of the first 5 s post-induction bursts. The results of 20 induction bursts were averaged for each animal. Arrhythmic CR (%) refers to the percentage of post-burst windows with a CR greater than the arrhythmic threshold (1.236). For additional details, see the Methods. Values are given as the mean ± s.e.m. Statistical analysis: for the electrophysiological parameters, the Student’s t-test was applied; for arrhythmic parameters, the Mann–Whitney test was applied. *P < 0.05, **P < 0.01, ***P < 0.001.