Fig. 2 | npj Digital Medicine

Fig. 2

From: Human–machine partnership with artificial intelligence for chest radiograph diagnosis

Fig. 2

Scatterplot of swarm vs. CheXMax probabilistic diagnoses, with cases colored by ground truth. The scatterplots show that CheXMax and human swarms assign very different probabilities to each case (left image). The gray “Augmented Cases” range shows cases that were sent from CheXMax to the Swarm for augmentation. CheXMax has a high incidence of True Positives (blue-colored cases below the horizontal CheXMax Threshold line), but when the CheXMax gives a weak positive diagnosis (between 0.04008 and 0.055 on the y-axis), it is often incorrect (11 out of 15 cases correct, or an accuracy of 73%). Using a human swarm to re-classify these weak positive cases results in correctly labeling 14 out of 15 of the cases—an accuracy improvement of 20%. The cases on which the two diagnostic methods disagreed are more clearly visualized in the scatterplot of diagnostic disagreement (right image).