Table 1 Values of the fluorescence quantum yield and excited-state lifetime of measured nonswitchable proteins in comparison with the literature values.

From: Absolute quantum yield measurements of fluorescent proteins using a plasmonic nanocavity

Protein

\({\Phi} _{meas}^{\,}\)

\({\Phi} _{lit}^{\,}\)

\(\tau _{meas}^{\,}\left( {ns} \right)\)

τlit(ns)

Citrine

0.61 ± 0.01

0.5434, 0.7635

3.3

3.636

EGFP

0.61 ± 0.01

0.6029,30

2.6

2.4–2.729

mCherry

0.24 ± 0.02

0.2237,38,39,40,41,0.2342, 0.3416

1.6

1.437, 1.533,42, 1.816

Clover

0.79 ± 0.01

0.7640

3.1

3.243

mEGFP

0.59 ± 0.01

0.6043,44, 0.7345

2.6

2.59 [45]

mKate2

0.42 ± 0.01

0.3942, 0.4046, 0.6016

2.5

2.542, 2.616

mKO2

0.65 ± 0.01

0.6247

3.5

---

mNeonGreen

0.76 ± 0.01

0.8043

3.0

3.143

mOrange2

0.56 ± 0.01

0.6046,48

2.5

2.748

mPapaya

0.80 ± 0.01

0.8349

2.9

---

mPlum

0.12 ± 0.03

0.1046

1.0

---

mRuby2

0.35 ± 0.02

0.3840, 0.4542, 0.6716

2.4

2.416, 2.542

mTurquoise2

0.89 ± 0.01

0.9350

3.8

4.050

TagRFP

0.51 ± 0.01

0.4837

2.4

2.2–2.337

TagRFP-T

0.45 ± 0.01

0.4146, 0.4842

2.2

2.342

  1. The error in all excited-state lifetime measurements did not exceed 0.1 ns.