Table 1 In vivo statistics for comparison of means between ECED and control conditions

From: Electrokinetic convection-enhanced delivery for infusion into the brain from a hydrogel reservoir

Experiment

Exposure time (ms)

Outcome measurement

Units

Control

ECED

ECED - Control

p-value

In vivo

400

Distance 10% of max. intensity

mm

0.39 ± 0.11

0.88 ± 0.11

0.49 ± 0.11

0.01a

In vivo

400

Distance 30% of max. intensity

mm

0.10 ± 0.06

0.33 ± 0.07

0.23 ± 0.06

0.04a

In vivo

400

Fluo. peak displacement

mm

0.08 ± 0.02

0.21 ± 0.03

0.13 ± 0.02

0.01a

In vivo

400

Fluo. peak intensity

%

35.13 ± 13.95

51.45 ± 12.39

16.32 ± 13.17

0.40

In vivo

400

Area within 10% of max. intensity

mm2

0.35 ± 0.21

1.30 ± 0.26

0.95 ± 0.23

0.02a

In vivo

400

Area within 30% of max. intensity

mm2

0.07 ± 0.06

0.22 ± 0.09

0.16 ± 0.07

0.16

  1. aindicates an unequal variances t-test p-value of p < 0.05. Data presented as mean ± standard error of the mean.
  2. Statistical test to calculate p-value: Welch’s t-test for unequal variances.