Table 1 The CFD simulation of VerMES two-impeller model
From: Defective flow space limits the scaling up of turbulence bioreactors for platelet generation
Scale | Speed | Turbulent energy | Shear stress | Kolmogorov scale | Shear rate | Vorticity | Dissipation of energy |
|---|---|---|---|---|---|---|---|
(L) | (mm s-1) | (m2 s-2) | (Pa) | (μm) | (s-1) | (s-1) | (m2 s-3) |
3 | 150 | 0.0129 | 3.93 | 150 | 17.29 | 13.4 | 0.099 |
10 | 150 | 0.0113 | 3.29 | 201 | 10.53 | 7.79 | 0.062 |
50 | 200 | 0.0082 | 2.38 | 286 | 5.60 | 4.46 | 0.023 |
50 | 300 | 0.0109 | 3.18 | 264 | 6.67 | 5.27 | 0.038 |
50 | 400 | 0.0220 | 6.41 | 194 | 8.64 | 6.80 | 0.097 |