Abstract
In the Rehabilitation Institute at Konstancin investigations and clinical tests have been carried out over the last ten years with a view to restoring the tetraplegic hand function by means of implanted stimulation of the peripheral nerves of the upper extremity. Lately, an apparatus for a tetraplegic has been constructed, based on patient controlled stimulation of the median and radial nerves. In this report the principle of the apparatus and also the initial clinical tests are discussed.
Investigations carried out so far have demonstrated that grasping function of the hand is compatible with the projected programme and that the induced function of the hand is useful for the patient.
Similar content being viewed by others
Log in or create a free account to read this content
Gain free access to this article, as well as selected content from this journal and more on nature.com
or
References
Kiwerski, J (1973). The effects of electrical stimulation on paralysed muscles in quadriplegics. Pol. Tyg. Lekarski, 28, 158.
Kiwerski, J & Paśniczek, R (1973). Early results of application of implanted stimulators in paralysis of upper extremities following spinal injury. Neurol. Neurochir. Polska, 7, 811.
Kiwerski, J, Weiss, M & Paśniczek, R (1979). Electrostimulation of the median nerve in tetraplegias by means of implanted stimulators. J. of Rehabilitation Research, 2, 41.
Kiwerski, J & Chrostowska, T (1980). Comparison of results of treatment of patients with cervical spine injuries in successive six-years periods. Chir. N. Ruchu i Ortop. Pol., 45, 109.
Morecki, A, Kiwerski, J, Paśniczek, R, Borowski, H & Gasztold, H (1978). New conception of the hybrid system of supporting of the grasping movements. Advances in External Control of Human Extremities. Yugoslav Committee for Electronics and Automation. Belgrade, p. 147.
Morecki, A, Weiss, M, Kiwerski, J & Paśniczek, R (1980). A new method for forcing lost grasping functions of extremities by use of an orthotic manipulator combined with implanted stimulator of nerves. International Conference on Medical Device and Sport Equipment. The American Soc. of Mechanical Engineers. San Francisco, Calif., p. 89.
Paśniczek, R, Kiwerski, J, Borowski, H & Wirski, J (1972). Some problems of implant stimulation applied to grasp motion. The Fourth International Symposium on External Control of Human Extremities. Dubrovnik, p. 584.
Paśniczek, R, Kiwerski, J & Białokoz, F (1979). Implanted stimulating electrodes for the stimulation of tissue in a living organism. Probl. Techn. Med., 10, 185.
Author information
Authors and Affiliations
Additional information
Paper read at the I.M.S.P. Meeting in Athens, Greece, October 1982.
Rights and permissions
About this article
Cite this article
Kiwerski, J., Pasniczek, R. An apparatus making possible restoration of simple functions of the tetraplegic hand. Spinal Cord 22, 316–319 (1984). https://doi.org/10.1038/sc.1984.51
Issue date:
DOI: https://doi.org/10.1038/sc.1984.51