Table 1 Details of the individual arrays of solar panels.
From: Multiyear microgrid data from a research building in Tsukuba, Japan
Array # | 1 | 2 | 3 a | 4 | Total | ||
|---|---|---|---|---|---|---|---|
Location | East and West sides, roof | Centre, roof | Centre, roof | South side, wall | Â | ||
Installation type | Mounted about 3 m high | Building integrated | Building integrated | Building integrated |  | ||
Capacity (kWp) | 50.92 | 24.74 | 11.40 | 3.78 | 90.84 | ||
Contribution to total capacity (%) | 56.05 | 27.23 | 12.55 | 4.16 | 100 | ||
Type of crystalline silicon | mono | poly | mono | poly | Â | ||
Approximate altitude angle (°) | 10 | 3b 357b | 2b 358b | 45 |  | ||
Brand | Sharp | Kyocera | Sharp | Sharp | Â | ||
Module type | NQ-134LW | MSRII-PVP62AK | NUOD062-067 | NUOD058-061 | ND-VOL7H | Â | |
# of panels | 380 | 200 (south) | 199 (north) | 36 | 24 | 18 | 857 |
Panel size (m) dimension 1 | 1.311 | 1.385 | 1.940 | 1.740 | 1.652 | Â | Â |
Panel size (m) dimension 2 | 0.668 | 0.455 | 0.9665 | 0.9665 | 0.994 | Â | Â |
Area (m2) (total panels) | 332.78 | 251.44 | 67.50 | 40.36 | 29.56 | Â | 721.64 |
Nominal output per panel effective surface (Wp) | 133.5 | 62 | 196 | 178 | 210 | Â | Â |