Table 1 EIS parameters fitted from the equivalent circuit and corresponding photovoltaic performance of DSCs with different counter electrodes in conjunction with T−/T2 electrolyte under 1 sun illumination (AM 1.5G, 100 mW cm−2)[a]
Electrodes | Rs [Ω] | Rct [Ω] | Cdl[F] | Voc[mV] | Jsc[mA cm−2] | FF | PCE[%] |
---|---|---|---|---|---|---|---|
Pt | 26.08±0.12 | 76.28±2.37 | (4.93±0.24)E-8 | 612±4 | 10.26±0.29 | 0.56±0.02 | 3.49±0.17 |
VASWCNTs | 25.67±0.08 | 12.66±1.85 | (4.60±0.43)E-6 | 610±3 | 12.66±0.35 | 0.68±0.03 | 5.25±0.23 |