Table 2 Determination of Cu2+ ion content in water samples
From: A colorimetric chemosensor for Cu2+ ion detection based on an iridium(III) complex
Complex | Sample | [Cu2+]/μM | Spiked [Cu2+]/μM | Found [Cu2+]/μM | Recovery (%) |
---|---|---|---|---|---|
1 | Tap water 1 | 0.89 | 2 | 2.65 ± 0.08 | 88 |
1 | Tap water 1 | 0.89 | 0.05 | 0.93 ± 0.06 | 80 |
1 | Tap water 2 | 0.67 | 2 | 2.45 ± 0.09 | 89 |
1 | Tap water 2 | 0.67 | 0.05 | 0.735 ± 0.06 | 130 |
1 | Shin Mun River | 0 | 2 | 1.565 ± 0.105 | 78.25 |
1 | Shin Mun River | 0 | 0.05 | 0.059 ± 0.01 | 118 |
2 | Tap water 1 | 0.89 | 2 | 2.73 ± 0.3 | 92 |
2 | Tap water 1 | 0.89 | 0.05 | 0.92 ± 0.06 | 60 |
2 | Tap water 2 | 0.67 | 2 | 2.77 ± 0.12 | 105 |
2 | Tap water 2 | 0.67 | 0.05 | 0.71 ± 0.06 | 80 |
2 | Shin Mun River | 0 | 2 | 1.695 ± 0.035 | 84.75 |
2 | Shin Mun River | 0 | 0.05 | 0.067 ± 0.003 | 134 |
3 | Tap water 1 | 0.89 | 2 | 3.085 ± 0.035 | 109.75 |
3 | Tap water 1 | 0.89 | 0.05 | 0.925 0.055 | 70 |
3 | Tap water 2 | 0.67 | 2 | 2.365 ± 0.215 | 84.75 |
3 | Tap water 2 | 0.67 | 0.05 | 0.735 ± 0.005 | 130 |
3 | Shin Mun River | 0 | 2 | 1.665 ± 0.115 | 83.25 |
3 | Shin Mun River | 0 | 0.05 | 0.065 ± 0.005 | 130 |