Table 1 Direct comparison of manual slice-by-slice segmentations from physician 1 and semi-automatic segmentation results for twelve ablation zones (AZ) via the Dice Similarity Coefficient (DSC).

From: Interactive Volumetry Of Liver Ablation Zones

No.

volume of AZ (mm3)

number of voxels

DSC (%)

manual

automatic

manual

automatic

1

30592.2

38900.5

55246

70208

81.98

2

18059.4

27123.2

32785

49175

71.78

3

13785.6

16672.5

8255

9988

72.75

4

32216.4

24520.8

18870

14348

76.36

5

33560.7

22190.1

58742

38852

72.49

6

40618.7

36919.6

28974

26319

82.23

7

122617

104022

70806

60113

83.43

8

12438.4

18105.4

21328

31069

73.05

9

9950.5

6253.58

5866

3689

71.94

10

49762.4

50814.2

34118

34835

83.53

11

40484

25717.6

26122

16593

75.85

12

26151.3

25146.7

14426

13887

78.28