Table 1 Geometrical specification of the microchannel employed in the present study.
From: A simple and novel way of maintaining constant wall temperature in microdevices
Feature | Size | Uncertainty | Units |
---|---|---|---|
Smaller Width (Wi) | 270 | + 2 | μm |
Larger Width (Wo) | 3052 | + 2 | μm |
Length (L) | 20 | −0.1 | mm |
Height (H) | 86 | ± 1 | μm |
Divergence Angle (θ) | 8 | 0.5 | ° |
Hydraulic Diameter (Dh) | 157 | 1.33 | μm |