Table 2 Determined key emission parameters based on ventilated chamber C-history method at 5 different AHs.
AH (g/m3) | Cm,0 (μg/m3) | Dm (m2/s) | K | R2 |
---|---|---|---|---|
Formaldehyde | ||||
4.6 ± 0.5 | 2.07 × 106 | 8.57 × 10−11 | 1.34 × 103 | 0.90 |
9.2 ± 0.5 | 4.63 × 106 | 1.49 × 10−10 | 2.06 × 103 | 0.99 |
12.7 ± 0.5 | 5.98×106 | 1.10 × 10−10 | 3.04 × 103 | 0.98 |
15.0 ± 0.5 | 1.43 × 107 | 1.31 × 10−10 | 3.61 × 103 | 0.98 |
20.0 ± 0.5 | 2.39 × 107 | 1.14 × 10−10 | 4.33 × 103 | 0.94 |
Hexaldehyde | ||||
4.6 ± 0.5 | 2.26 × 105 | 1.63 × 10−10 | 1.61 × 102 | 0.93 |
9.2 ± 0.5 | 3.66 × 105 | 2.27 × 10−10 | 1.81 × 102 | 0.93 |
12.7 ± 0.5 | 5.42 × 105 | 1.17 × 10−10 | 2.34 × 102 | 0.98 |
15.0 ± 0.5 | 6.49 × 105 | 1.86 × 10−10 | 2.69 × 102 | 0.93 |
20.0 ± 0.5 | 6.91 × 105 | 1.16 × 10−10 | 2.80 × 102 | 0.98 |