Table 2 The mechanical performances of EPTs.

From: Tantalum implanted entangled porous titanium promotes surface osseointegration and bone ingrowth

EPTs

Yielding stress (MPa)

Young’s modulus (MPa)

Unimplanted EPT

7.27 ± 0.31

114.30 ± 5.86

Ca-implanted EPT

7.20 ± 0.26

119.00 ± 2.65

Ta-implanted EPT

7.37 ± 0.57

117.30 ± 11.37