Table 3 Comparisons of the calculation time, average prediction accuracy and forecast error between two models.

From: In Vivo Investigation of the Effectiveness of a Hyper-viscoelastic Model in Simulating Brain Retraction

 

Calculation time(s)

Average prediction accuracy (%)

Average forecast error (mm)

the Hyper-viscoelastic XFEM model

the Linear Elastic XFEM model

the Hyper-viscoelastic XFEM model

the Linear Elastic XFEM model

the Hyper-viscoelastic XFEM model

the Linear Elastic XFEM model

Subject #1

21

31

80.5

82.4

0.4

0.4

Subject #2

53

Fail

73.9

0.3

Subject #3

21

Fail

80.0

0.3

Subject #4

19

Fail

87.2

0.4

Subject #5

26

Fail

71.5

0.8

Subject #6

33

Fail

82.9

0.4

Subject #7

30

40

82.9

84.9

0.4

0.3