Table 1 Data fitting (see Fig. 1A) relative to the evaluation of the IC50 values of Cu(II) and Zn(II) ions for ChT-L, T-L and C-L peptidase activity of the CP.Curve fitting was performed by using Equation 1.
From: Copper(II) ions affect the gating dynamics of the 20S proteasome: a molecular and in cell study
ChT-L | T-L | C-L | ||||
---|---|---|---|---|---|---|
Cu(II) | Zn(II) | Cu(II) | Zn(II) | Cu(II) | Zn(II) | |
IC50 (μM) | 1.19 | 5.99 | 1.45 | 4.16 | 1.01 | 5.84 |
95% Confidence Intervals | 0.67 to 2.09 | 2.98 to 12.30 | 0.98 to 2.14 | 1.65 to 10.53 | 0.66 to 1.56 | 4.94 to 6.90 |
R2 | 0.91 | 0.91 | 0.96 | 0.81 | 0.95 | 0.99 |