Table 2 HP-SEC column interaction of MEDI1912 variants.

From: Engineering the surface properties of a human monoclonal antibody prevents self-association and rapid clearance in vivo

Antibody

Mutations

HP-SEC monomer retention time (mins)

Reference IgG

N/A

8.7

MEDI-578

N/A

8.7

MEDI1912 (WFL)

15.0

Mutant 1 (WFT)

L56T

12.3

Mutant 2 (WTL)

F31T

10.3

Mutant 3 (SFL)

W30S

10.3

Mutant 4 (SFT)

W30S, L56T

9.7

Mutant 5 (STL)

W30S, F31T

9.0

Mutant 6 (STT)

W30S, F31T, L56T

8.9