Table 1 Summary of the estimated heat loads on the SN2 cooling system.

From: Solid cryogen: a cooling system for future MgB2 MRI magnet

Thermal heat load

Radiation shield (W)

SN2 chamber (W)

Conduction

15.64

0.37

Current lead joule heating at 200 A

26.49

0.26

Radiation (10 layered MLI was used)

2.63

0.01

Residual gas conduction

0.34

0.08

Total (W) (without current)

18.61

0.46

Total (W) (with 200 A current)

45.10

0.72