Table 1 Impact and tensile testing data of Cu samples.
From: Effect of grain structure on Charpy impact behavior of copper
Cu samples | Mechanical properties | |||||
---|---|---|---|---|---|---|
Ak (J) | ak (J/cm2) | Fyeild (N) | Fmax (N) | εu(%) | σuts (MPa) | |
CG | 4.8 ± 0.1 | 55 ± 2 | 65 ± 5 | 650 ± 5 | 50 | 200 |
ECAP-2 | 4.4 ± 0.1 | 48 ± 2 | 790 ± 5 | 865 ± 5 | 1 | 370 |
ECAP-16 | 4.4 ± 0.1 | 48 ± 2 | 790 ± 5 | 880 ± 5 | 2 | 400 |