Table 1 Output parameters of the uniform design.

From: Integrating uniform design and response surface methodology to optimize thiacloprid suspension

No.

Aqueous separation ratio (%)

Viscosity (mPa·s)

Suspensibility (%)

Before storage

After storage

U-1

3.92 ± 0.29 f

362.3 ± 1.8a

94.11 ± 1.59 ab

91.95 ± 1.76 a

U-2

6.27 ± 0.31e

300.0 ± 1.9c

92.89 ± 2.18 b

91.09 ± 2.53 a

U-3

7.92 ± 0.14d

278.1 ± 1.5e

94.34 ± 1.22 ab

93.10 ± 1.52 a

U-4

15.04 ± 0.24b

308.6 ± 1.5b

94.39 ± 1.30 ab

93.31 ± 1.19 a

U-5

2.75 ± 0.20 g

284.2 ± 2.7d

94.74 ± 2.16 ab

91.42 ± 2.11 a

U-6

6.47 ± 0.24e

359.6 ± 2.7a

95.16 ± 1.06 ab

92.92 ± 1.26 a

U-7

1.74 ± 0.24 h

364.9 ± 1.6a

97.62 ± 1.44 a

93.71 ± 6.36 a

U-8

30.63 ± 0.23a

267.8 ± 2.3 f

95.55 ± 1.61 ab

95.00 ± 2.71 a

U-9

13.60 ± 0.22c

302.3 ± 3.6c

96.40 ± 1.62 ab

94.19 ± 1.02 a

  1. Note: Data are displayed as the mean ± SD (standard deviation). Data of the same index with different lowercase letters are significantly different at the p < 0.05 level based on Tukey’s test.