Table 9 Orthogonal experiment results.
j | i | Pre-sieve airflow Yi | Rear sieve airflow Ki | Cross-sectional airflow uniformity Ti | ||||
|---|---|---|---|---|---|---|---|---|
A Fan speed | B Inclination angle of the first guide plate | C Opening degree of the fish-scale sieve | D Inclination angle of the second guide plate | |||||
1 | 1 | 1 | 1 | 1 | 3.59 | 0.83 | 0.612 | |
2 | 1 | 2 | 4 | 2 | 3.31 | 1.07 | 0.482 | |
3 | 2 | 3 | 2 | 2 | 3.32 | 1.17 | 0.325 | |
4 | 2 | 4 | 3 | 1 | 3.48 | 1.16 | 0.421 | |
5 | 3 | 3 | 3 | 2 | 4.43 | 1.51 | 0.531 | |
6 | 3 | 4 | 2 | 1 | 4.68 | 1.54 | 0.345 | |
7 | 4 | 1 | 4 | 1 | 3.05 | 0.91 | 0.387 | |
8 | 4 | 2 | 1 | 2 | 2.95 | 1.16 | 0.361 | |
Cross-sectional airflow uniformity indicator | Tj1 | 1.10 | 1.00 | 0.97 | 1.77 | |||
Tj2 | 0.75 | 0.84 | 0.67 | 1.70 | ||||
Tj3 | 0.88 | 0.86 | 0.95 | |||||
Tj4 | 0.75 | 0.77 | 0.87 | |||||
Rj | 0.35 | 0.23 | 0.30 | 0.07 | ||||
R’ | 0.22 | 0.15 | 0.19 | 0.09 | ||||
Optimal parameter combination | ACBD A2C2B4D2 | |||||||
Pre-sieve airflow indicator | Yj1 | 6.9 | 6.64 | 6.54 | 14.8 | |||
Yj2 | 6.8 | 6.26 | 8 | 14.01 | ||||
Yj3 | 9.11 | 7.75 | 7.91 | |||||
Yj4 | 6 | 8.16 | 6.36 | |||||
Rj | 3.11 | 1.9 | 1.64 | 0.79 | ||||
R’ | 1.98 | 1.21 | 1.06 | 1.12 | ||||
Optimal parameter combination | ABDC A3B4D1C2 | |||||||
Rear sieve airflow indicator | Kj1 | 1.9 | 1.74 | 1.99 | 4.44 | |||
Kj2 | 2.33 | 2.23 | 2.71 | 4.91 | ||||
Kj3 | 3.05 | 2.68 | 2.67 | |||||
Kj4 | 2.07 | 2.7 | 1.98 | |||||
Rj | 1.15 | 0.96 | 0.73 | 0.47 | ||||
R’ | 0.73 | 0.61 | 0.47 | 0.67 | ||||
Optimal parameter combination | ADBC A3D2B4C2 | |||||||