Table 5 Robustness analysis of BTO, CAO, DEA and SOA for 85-bus RDS (Case 2).

From: A barrel theory-based optimization of stochastic PV-DG integration in radial distribution networks under load and solar uncertainties

Robustness analysis (kW)

BTO

CAO

DEA

SOA

Minimum probabilistic losses

81.95196

82.84922

84.79962

83.71631

Mean probabilistic losses

82.73703

89.44064

87.19995

96.34019

Maximum probabilistic losses

83.6868

102.3063

89.54375

161.6351

Standard Dev. probabilistic losses

0.477595

4.53564

1.177662

17.45912