Abstract
Purpose To assess the influence of visually significant cataract on the measurement of nerve fibre layer thickness by scanning laser polarimetry (GDx) in glaucoma patients undergoing phacoemulsification cataract extraction.
Method and Subjects All subjects with primary glaucoma participating in a prospective trial of glaucoma surgery who subsequently underwent cataract extraction were eligible. A single trained observer using the GDx nerve fibre layer analyser (LDT) performed pre- and post-operative measurements of nerve fibre layer thickness (NFLT). NFLT parameters, best-corrected LogMAR visual acuity, and automated visual fields were assessed before and after phacoemulsification cataract extraction with implantation of an acrylic intraocular lens.
Results A total of 49 subjects were assessed: 22 (45%) had POAG and 29 (55%) PACG; all were Asian (36 (73%) were Chinese), with mean age 67.1 (±7.6 SD) and mean ‘LOCS III’ lens opacity grading 11.4 (±3.1 SD). Visual acuity significantly improved (mean LogMAR 0.5 vs0.15, P<0.0001). Corrected pattern standard deviation (6.1 vs6.4, P=0.2) and mean deviation (−17.7 dB vs-17.0 P=0.91) were little changed after cataract removal. Pseudo-phakic measurements of NFLT were significantly different from pre-op values. Measures of absolute thickness (including the average thickness, ellipse, ellipse average, superior and inferior averages, superior integral) were significantly greater than preoperative values (all P<0.01), whereas ratios and measures of symmetry (symmetry, superior/nasal) were unchanged (all P>0.1) and ‘the number’ was smaller (P=0.04). Differences in measured NFLT were most strongly correlated with posterior subcapsular cataract (average thickness, P=0.01).
Conclusions Removal of cataract resulted in greater absolute measurements of NFLT but ratio values were unchanged. Scanning laser polarimetry measurements can change significantly after cataract extraction. New baseline measurements may be required.
Similar content being viewed by others
Log in or create a free account to read this content
Gain free access to this article, as well as selected content from this journal and more on nature.com
or
References
Quigley HA, Addicks EM, Green WR . Optic nerve damage in human glaucoma. III. Quantitative correlation of nerve fibre loss and visual field defect in glaucoma, ischaemic optic neuropathy, disc oedema and toxic neuropathy. Arch Ophthalmol 1982; 100: 135–139.
Antón A, Maquet JA, Mayo A, Tapia J, Pastor JC . Value of logistic discriminant analysis for interpreting initial visual field defects. Ophthalmology 1997; 104: 525–531.
Chauhan BC, Drance SM, Douglas GR . The use of visual field indices in detecting changes in the visual field in glaucoma. Invest Ophthalmol Vis Sci 1990; 31: 512–520.
Keltner JL, Johnson CA, Quigg JM, Cello KE, Kass MA, Gordon MO . Confirmation of visual field abnormalities in the Ocular Hypertension Treatment Study. Ocular Hypertension Treatment Study Group. Arch Ophthalmol 2000; 118: 1187–1194.
Sommer A, Katz J, Quigley HA, Miller NR, Robin AL, Richter RC et al. Clinically detectable nerve fibre atrophy preceeds the onset of glaucomatous visual loss. Arch Ophthalmol 1990; 109: 77–83.
Kamal DS, Bunce C, Hitchings RA . Use of the GDx to detect differences in retinal nerve fibre layer thickness between normal, ocular hypertensive and early glaucomatous eyes. Eye 2000; 14: 367–370.
Kamal DS, Viswanathan AC, Garway-Heath DF, Hitchings RA, Poinoosawmy D, Bunce C . Detection of optic disc change with the Heidelberg retina tomograph before confirmed visual field change in ocular hypertensives converting to early glaucoma. Br J Ophthalmol 1999; 83: 290–294.
Ugurlu S, Hoffman D, Garway-Heath DF, Caprioli J . Relationship between structural abnormalities and short-wavelength perimetric defects in eyes at risk of glaucoma. Am J Ophthalmol 2000; 129: 592–598.
Hoh ST, Ishikawa H, Greenfield DS, Liebmann JM, Chew SJ, Ritch R . Peripapillary nerve fiber layer thickness measurement reproducibility using scanning laser polarimetry. J Glaucoma 1998; 7: 12–15.
Colen TP, Tjon-Fo-Sang MJ, Mulder PG, Lemij HG . Reproducibility of measurements with the nerve fiber analyzer (NfA/GDx). J Glaucoma 2000; 9: 363–370.
Kook MS, Sung K, Park RH, Kim KR, Kim ST, Kang W . Reproducibility of scanning laser polarimetry (GDx) of peripapillary retinal nerve fiber layer thickness in normal subjects. Graefes Arch Clin Exp Ophthalmol 2001; 239: 118–121.
Weinreb RN, Shakiba S, Zangwill L . Scanning laser polarimetry to measure the nerve fiber layer of normal and glaucomatous eyes. Am J Ophthalmol 1995; 119: 627–636.
Lee VW, Mok KH . Nerve fibre layer measurement of the Hong Kong Chinese population by scanning laser polarimetry. Eye 2000; 14: 371–374.
Poinoosawmy D, Fontana L, Wu JX, Fitzke FW, Hitchings RA . Variation of nerve fibre layer thickness measurements with age and ethnicity by scanning laser polarimetry. Br J Ophthalmol 1997; 81: 350–354.
Sens FM, Mojon DS, Fleischhauer J, Bergamin O, Bohnke M . Measuring nerve fiber thickness with laser scanning polarimetry in aging. Klin Monatsbl Augenheilk 1998; 212: 261–263.
Choplin NT . Effect of corneal polarization axis on assessment of retinal nerve fiber layer on thickness by scanning laser polarimetry. Am J Ophthalmol 2001; 131: 528–529.
Choplin NT, Schallhorn SC . The effect of excimer laser photorefractive keratectomy for myopia on nerve fiber layer thickness measurements as determined by scanning laser polarimetry. Ophthalmology 1999; 106: 1019–1023.
Gurses-Ozden R, Pons ME, Barbieri C, Ishikawa H, Buxton DF, Liebmann JM et al. Scanning laser polarimetry measurements after laser-assisted in situ keratomileusis. Am J Ophthalmol 2000; 129: 461–464.
Chiba T, Kogure S, Tsukahara S . Influence of cataract on scanning laser polarimetry. Nippon Ganka Gakkai Zasshi—Acta Soc Ophthalmol Jpn 2000; 104: 626–630.
Chiba T, Kogure S, Tsukahara S . Influence of cataract on scanning laser polarimetry. J Ophthalmol 2000; 45(2): 202–203.
Hoh ST, Greenfield DS, Liebmann JM, Hillenkamp J, Ishikawa H, Mistlberger A et al. Effect of pupillary dilation on retinal nerve fiber layer thickness as measured by scanning laser polarimetry in eyes with and without cataract. J Glaucoma 1999; 8: 159–163.
Kremmer S, Pflug A, Heiligenhaus A, Fanihagh F, Steuhl KP . Laser scanning topography and polarimetry with implantation of intraocular lenses before and after cataract surgery. Klin Monatsbl Augenheilk 1999; 214: 378–385.
Park RJ, Chen PP, Karyampudi P, Mills RP, Harrison DA, Kim J . Effects of cataract extraction with intraocular lens placement on scanning laser polarimetry of the peripapillary nerve fiber layer. Am J Ophthalmol 2001; 132: 507–511.
Collur S, Carroll AM, Cameron BD . Human lens effect on in vivo scanning laser polarimetric measurements of retinal nerve fiber layer thickness. Ophthalmic Surg Lasers 2000; 31: 126–130.
Chylack Jr LT, Wolfe JK, Singer D, Leske MC, Bullimore MA, Bailey IL et al. Lens opacity classification system III. Arch Ophthalmol 1993; 111: 831–836.
Weinreb RN, Zangwill L, Berry CC, Bathija R, Sample PA . Detection of glaucoma with scanning laser polarimetry. Arch Ophthalmol 1998; 116: 1583–1589.
Yamada N, Tomita G, Yamamoto T, Kitazawa Y . Changes in the nerve fiber layer thickness following a reduction of intraocular pressure after trabeculectomy. J Glaucoma 2000; 9(5): 371–375.
Chen PP, Budenz DL . The effects of cataract extraction on the visual field of eyes with chronic open-angle glaucoma. Am J Ophthalmol 1998; 125: 325–333.
Greenfield DS, Knighton RW, Feuer WJ, Schiffman JC, Zangwill L, Weinreb RN . Correction for corneal polarization axis improves the discriminating power of scanning laser polarimetry. Am J Ophthalmol 2002; 134: 27–33.
Greenfield DS, Knighton RW, Huang XR . Effect of corneal polarization axis on assessment of retinal nerve fiber layer thickness by scanning laser polarimetry. Am J Ophthalmol 2000; 129: 715–722.
Greenfield S, Knighton RW, Huang X . Effect of corneal polarization axis on assessment of retinal nerve fiber layer thickness by scanning laser polarimetry. Am J Ophthalmol 2001; 131: 403–404.
Weinreb RN, Bowd C, Greenfield DS, Zangwill LM . Measurement of the magnitude and axis of corneal polarization with scanning laser polarimetry. Arch Ophthalmol 2002; 120: 901–906.
Greenfield DS, Knighton RW . Stability of corneal polarization axis measurements for scanning laser polarimetry. Ophthalmology 2001; 108: 1065–1069.
Author information
Authors and Affiliations
Corresponding author
Additional information
Funding and support by Singapore National Medical Research Council NMRC/0044/1994, Singapore National Eye Centre, and Medical Research Council (UK) G9330070 (Professor Khaw)
Commercial relationships or conflict of interest: None
Rights and permissions
About this article
Cite this article
Gazzard, G., Foster, P., Devereux, J. et al. Effect of cataract extraction and intraocular lens implantation on nerve fibre layer thickness measurements by scanning laser polarimeter (GDx) in glaucoma patients. Eye 18, 163–168 (2004). https://doi.org/10.1038/sj.eye.6700600
Received:
Accepted:
Published:
Issue date:
DOI: https://doi.org/10.1038/sj.eye.6700600
Keywords
This article is cited by
-
Rates of retinal nerve fibre layer thickness change in glaucoma patients and control subjects
Eye (2012)
-
Effect of posterior capsular opacification removal on scanning laser polarimetry measurements
Graefe's Archive for Clinical and Experimental Ophthalmology (2006)