Key Points
-
Osseo-integrated dental implants are a successful way of supporting missing units.
-
Implant fracture is a relatively uncommon complication.
-
Implant placement and restoration require careful consideration in order to avoid such complications.
-
When implant fracture occurs the fixture may be left in situ, removed, or salvaged if the fracture occurs at a favourable level.
Abstract
Osseo-integrated dental implants offer a predictable treatment for the replacement of missing teeth.1,2,3 Despite the high success, complications can occur such as loss of integration, peri-implantitis and mucositis as well as mechanical problems. The latter includes screw loosening and more significantly fracture of the implant itself. As implant use is increasing, practitioners are more likely to face, and have to deal with, such complications. This report describes the management of a patient with a fractured Brånemark fixture in the maxilla. The likely causes are discussed and the treatment options highlighted together with the decision making process which lead to the final management.
Similar content being viewed by others
Log in or create a free account to read this content
Gain free access to this article, as well as selected content from this journal and more on nature.com
or
References
Adell R, Lekholm U, Rockler B, Branemark P I . A 15-year study of osseointegrated implants in the treatment of the edentulous jaw. Int J Oral Surg 1981; 10: 387–416.
Zarb G A, Scmitt A . The longitudinal clinical effectiveness of osseointegrated dental implants: the Toronto study. Part III: Problems and complications encountered. J Prosthet Dent 1990; 64: 185–194.
Lekholm U, Gunne J, Henry P et al. Survival of the Brånemark implant in partially edentulous jaws: a 10 year prospective multicentre study. Int J Oral Maxillofac Implants 1999; 14: 639–645.
Naert I, Quirynen M, van Steenberge D, Darius P . A study of 589 consecutive implants supporting complete fixed prostheses. Part II: Prosthetic aspects. J Prosthet Dent 1992; 68: 949–956.
Pylant T, Triplett R G, Key M C, Brunsvold M A . A retrospective evaluation of endosseous titanium implants in the partially edentulous patient. Int J Oral Maxillofac Implants 1992; 7: 195–202.
Tolman D E, Laney W R . Tissue-integrated dental prostheses: the first 78 months of experience at the Mayo Clinic. Mayo Clin Proc 1993; 68: 323–331.
Henry P J, Laney W R, Jemt T et al. Osseointegrated implants for single tooth replacement: a prospective 5-year multicentre study. Int J Oral Maxillofac Implants 1996; 11: 450–455.
Balshi T J . An analysis and management of fractured implants: a clinical report. Int J Oral Maxillofac Implants 1996; 11: 660–666.
Allen P F, McMillan A S, Smith D G . Complications and maintenance requirements of implant-supported prostheses provided in a UK dental hospital. Br Dent J 1997; 182: 298–302.
Eckert S E, Meraw S J, Cal E, Ow R K . Analysis of incidence and associated factors with fractured implants: a retrospective study. Int J Oral Maxillofac Implants 2000; 15: 662–667.
Levine R A, Clem D S, Wilson T G et al. Multicentre retrospective analysis of the ITI system used for single tooth replacements: results of loading for two or more years. Int J Oral Maxillofac Implants 1999; 14: 516–520.
Piattelli A, Scarano A, Piattelli M et al. Hallow implants retrieved for fracture: a light and scanning electron microscope analysis of 4 cases. J Periodontol 1998; 69: 185–189.
Tagger Green N, Machtei E E, Horwitz J, Peled M . Fracture of dental implants: a literature review and report of a case. Implant Dent 2002; 11: 137–143.
Ibbott C G . In vivo fracture of a basket type osseointegrating dental implant: a case report. Int J Oral Maxillofac Implants 1989; 4: 255–256.
Brunel G, Armand S, Miller N, Rue J . Histologic analysis of a fractured implant: a case report. Int J Periodontics Restorative Dent 2000; 20: 521–526.
Rangert B, Jemt T, Jörnéus L . Forces and moments on Branemark implants. Int J Oral Maxillofac Implants 1989; 4: 241–247.
Rangert B, Krogh P H J, Langer B, Roekel N V . Bending overload and implant fracture: a retrospective clinical analysis. Int J Oral Maxillofac Implants 1995; 10: 326–334.
Rangert B, Sullivan R . Biomechanical principles preventing prosthetic overload induced by bending. Nobelpharma News 1993; 7: 4–5.
Yokoyama K, Ichikawa T, Murakami H, Miyamoto Y, Asaoka K . Fracture mechanisms of retrieved titanium screw thread in dental implant. Biomaterials 2002; 23: 2,459–2,465.
Morgan M J, James D F, Pillar R M . Fractures of the fixture component of an osseointegrated implant. Int J Oral Maxillofac Implants 1993; 8: 409–414.
Velasquez-Plata D, Lutonsky J, Oshida Y, Jones R . A close up look at an implant fracture: a case report. Int J Periodontics Restorative Dent 2002; 22: 482–491.
Gibney K . Fracture of the body of an implant and its management – a case history. Br Dent J 2004; 197: 615–617.
Bahat O, Handelsman M . Use of wide implants and double implants in the posterior jaw: a clinical report. Int J Oral Maxillofac Implants 1996; 11: 379–386.
Carr A B, Steward R B . Full-arch implant framework casting accuracy: preliminary in vitro observation for in vivo testing. J Prosthodont 1993; 2: 2–8.
Meijer H J, Kuiper J H, Starmans F J, Bosman F . Stress distribution around dental implants: Influence of superstructure, length of implants, and height of mandible. J Prosthet Dent 1992; 68: 96–102.
Watanabe F, Unu I, Hata Y, Neuendorff G, Kirsch A . Analysis of stress distribution in a screw-retained implant prosthesis. Int J Oral Maxillofac Implants 2000; 15: 209–218.
Wie H . Registration of localisation, occlusion and occluding materials for failing screw joints in the Brånemark implant system. Clin Oral Implants Res 1995; 6: 47–53.
Saba S . Occlusal stability in implant prosthodontics — clinical factors to consider before implant placement. J Can Dent Assoc 2001; 67: 522–526.
Ortorp A, Jemt T, Back T, Jalevik T . Comparisons of precision of fit between cast and CNC-milled titanium implant frameworks for the edentulous mandible. Int J Prosthodont 2003; 16: 194–200.
Wennstrom J L, Palmer R M . Proceedings of the 3rd European Workshop on Periodontology. In Lang N, Karring T, Lindhe J (eds) Implant dentistry. Berlin: Quintessense 1999.
Albrektsson T, Zarb G, Worthington P, Eriksson A R . The long-term efficacy of currently used dental implants: a review and proposed criteria of success. Int J Oral Maxillofac Implants 1986; 1: 11–25.
Quirynen M, Naert I, van Steenberge D. Fixture design and overload influence marginal bone loss and fixture success in the Brånemark system. Clin Oral Implants Res 1992; 3: 104–111.
Duyck J, Ronold H J, Van Oosterwyck H et al. The influence of static and dynamic loading on marginal bone reactions around osseointegrated implants: an animal experimental study. Clin Oral Implants Res 2001; 12: 207–218.
Author information
Authors and Affiliations
Corresponding author
Additional information
Refereed paper
Rights and permissions
About this article
Cite this article
Virdee, P., Bishop, K. A review of the aetiology and management of fractured dental implants and a case report. Br Dent J 203, 461–466 (2007). https://doi.org/10.1038/bdj.2007.948
Accepted:
Published:
Issue date:
DOI: https://doi.org/10.1038/bdj.2007.948
This article is cited by
-
Prosthodontic complications associated with implant retained crowns and bridgework: a review of the literature
British Dental Journal (2012)
-
No need for grafting
British Dental Journal (2008)


