Skip to main content

Thank you for visiting nature.com. You are using a browser version with limited support for CSS. To obtain the best experience, we recommend you use a more up to date browser (or turn off compatibility mode in Internet Explorer). In the meantime, to ensure continued support, we are displaying the site without styles and JavaScript.

Advertisement

Eye
  • View all journals
  • Search
  • Log in
  • Content Explore content
  • About the journal
  • Publish with us
  • Sign up for alerts
  • RSS feed
  1. nature
  2. eye
  3. articles
  4. article
The effect of anaesthesia on the intraocular volume of the C3F8 gas bubble
Download PDF
Download PDF
  • Article
  • Published: 01 January 1997

The effect of anaesthesia on the intraocular volume of the C3F8 gas bubble

  • M Briggs1,
  • D Wong1,
  • C Groenewald1,
  • J McGalliard1,
  • J Kelly2 &
  • …
  • J Harper2 

Eye volume 11, pages 47–52 (1997)Cite this article

  • 912 Accesses

  • 19 Citations

  • Metrics details

Abstract

Long-acting intraocular gas bubbles are frequently used during vitrectomy to tamponade retinal breaks. The aim of this study was to determine the effect of nitrous oxide anaesthesia on the size and effectiveness of the post-vitrectomy gas bubble. Twenty vitrectomy procedures with injection of 12% perfluoropropane (C3F8) gas were performed. For 10 of the cases routine anaesthesia with nitrous oxide was used and for 10 cases non-nitrous anaesthesia with propofol was used. The volume of the intraocular gas bubble was estimated 24 hours post-operatively using A-scan biometry. At 24 hours the gas bubble occupied a mean of 65.1% of the eye in anaesthesia with nitrous oxide and a mean of 66.1% in anaesthesia with intravenous propofol. The wide range of values of gas-fill recorded at 24 hours makes comparison of the two groups inappropriate. Several factors may account for this spread of values, but in our opinion it is the uncontrolled leakage from the sclerostomies which is the most likely. This study suggests that anaesthesia using nitrous oxide does not adversely affect the size of the C3F8 gas bubble at 24 hours post-vitredomy when compared with anaesthesia without nitrous oxide.

Similar content being viewed by others

Objective analysis of perfluoropropane tamponade area after pars plana vitrectomy using ultra-widefield fundus stereographic projection images

Article Open access 26 October 2020

Rise in intraocular pressure with elevator travel in post-vitrectomy patients

Article Open access 28 August 2023

Intraoperative choroidal detachment during small-gauge vitrectomy: analysis of causes, anatomic, and visual outcomes

Article Open access 21 June 2021

Article PDF

References

  1. Smith RB, Carl B, Linn JG, Nemoto E . Effect of nitrous oxide on gas bubble volume in the anterior chamber. Am J Ophthalmol 1974;78:14–27.

    Article  Google Scholar 

  2. Stinson TW, Donion JV Jr. Interaction of intraocular air and sulphur hexafluoride with nitrous oxide: a computer simulation. Anaesthesiology 1982;56:385.

    Article  CAS  Google Scholar 

  3. Wolf GL, Capuano C, Hartung J . Nitrous oxide increases intraocular pressure after intravitreal sulphur hexafluoride injection. Anaesthesiology 1983;59:547–8.

    Article  CAS  Google Scholar 

  4. Wolf GL, Capuano C, Hartung J . Effect of nitrous oxide on gas bubble volume in the anterior chamber. Arch Ophthalmol 1985;103:418–9.

    Article  CAS  Google Scholar 

  5. Lincoff H, Soloranzo C, Iwamoto T . Selection of xenon gas for rapidly disappearing retinal tamponade. Arch Ophthalmol 1982;100:996–7.

    Article  CAS  Google Scholar 

  6. Mostafa SM, Wong SHD, Snowdon SL, Ansons AM, Kelly JM, McGalliard JN . Nitrous oxide and internal tamponade during vitrectomy. Br J Ophthalmol 1991;75:726–8.

    Article  CAS  Google Scholar 

  7. Ament R . Origin of the ASA classification. Anesthesiology 1979;51:179.

    Article  CAS  Google Scholar 

  8. Jacobs PM, Twomey JM, Leaver PK . Behaviour of intraocular gases. Eye 1988;2:660–3.

    Article  Google Scholar 

  9. Jacobs PM . Intraocular gas measurement using A-scan ultrasound. Curr Eye Res 1986;5:575–8.

    Article  CAS  Google Scholar 

  10. Thompson JT, Michels RG . Volume displacement of scleral buckles. Arch Ophthalmol 1985;103:1822–4.

    Article  CAS  Google Scholar 

  11. Peters MA, Abrams GW, Hamilton LH, Burke JM, Schrieber TM . The non-expansile equilibrated concentration of perfluoropropane gas in the eye. Am J Ophthalmol 1985;100:831–9.

    Article  CAS  Google Scholar 

  12. Humayun MS, Haller Yeo J, Koski WS, Michels RG . The rate of sulphur hexafluoride escape from a plastic syringe. Arch Ophthalmol 1989;107:853–4.

    Article  CAS  Google Scholar 

  13. Bourgeois JE, Machemer R . The results of sulphur hexafluoride gas in vitreous surgery. Am J Ophthalmol 1983;96:405–7.

    Article  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

  1. St Paul's Eye Unit, Royal Liverpool University Hospital, Prescot Street, Liverpool, L7 8XP, UK

    M Briggs, D Wong, C Groenewald & J McGalliard

  2. Anaesthetic Department, Royal Liverpool University Hospital, Prescot Street, Liverpool, L7 8XP, UK

    J Kelly & J Harper

Authors
  1. M Briggs
    View author publications

    Search author on:PubMed Google Scholar

  2. D Wong
    View author publications

    Search author on:PubMed Google Scholar

  3. C Groenewald
    View author publications

    Search author on:PubMed Google Scholar

  4. J McGalliard
    View author publications

    Search author on:PubMed Google Scholar

  5. J Kelly
    View author publications

    Search author on:PubMed Google Scholar

  6. J Harper
    View author publications

    Search author on:PubMed Google Scholar

Rights and permissions

Reprints and permissions

About this article

Cite this article

Briggs, M., Wong, D., Groenewald, C. et al. The effect of anaesthesia on the intraocular volume of the C3F8 gas bubble. Eye 11, 47–52 (1997). https://doi.org/10.1038/eye.1997.10

Download citation

  • Issue date: 01 January 1997

  • DOI: https://doi.org/10.1038/eye.1997.10

Share this article

Anyone you share the following link with will be able to read this content:

Sorry, a shareable link is not currently available for this article.

Provided by the Springer Nature SharedIt content-sharing initiative

Keywords

  • Vitrectomy
  • Tamponade
  • C3F8
  • Intraocular gas
  • Anaesthesia
  • Nitrous oxide

This article is cited by

  • Glaukom und Netzhautchirurgie

    • M. Müller
    • G. Geerling
    • T. Klink

    Der Ophthalmologe (2010)

Download PDF

Advertisement

Explore content

  • Research articles
  • Reviews & Analysis
  • News & Comment
  • Current issue
  • Collections
  • Follow us on Twitter
  • Sign up for alerts
  • RSS feed

About the journal

  • Journal Information
  • Open Access Fees and Funding
  • About the Editors
  • Journal News
  • Special Issues
  • About the Partner
  • EYE Covers
  • Contact
  • For Advertisers
  • Subscribe

Publish with us

  • For Authors & Referees
  • Language editing services
  • Open access funding
  • Submit manuscript

Search

Advanced search

Quick links

  • Explore articles by subject
  • Find a job
  • Guide to authors
  • Editorial policies

Eye (Eye)

ISSN 1476-5454 (online)

ISSN 0950-222X (print)

nature.com sitemap

About Nature Portfolio

  • About us
  • Press releases
  • Press office
  • Contact us

Discover content

  • Journals A-Z
  • Articles by subject
  • protocols.io
  • Nature Index

Publishing policies

  • Nature portfolio policies
  • Open access

Author & Researcher services

  • Reprints & permissions
  • Research data
  • Language editing
  • Scientific editing
  • Nature Masterclasses
  • Research Solutions

Libraries & institutions

  • Librarian service & tools
  • Librarian portal
  • Open research
  • Recommend to library

Advertising & partnerships

  • Advertising
  • Partnerships & Services
  • Media kits
  • Branded content

Professional development

  • Nature Awards
  • Nature Careers
  • Nature Conferences

Regional websites

  • Nature Africa
  • Nature China
  • Nature India
  • Nature Japan
  • Nature Middle East
  • Privacy Policy
  • Use of cookies
  • Legal notice
  • Accessibility statement
  • Terms & Conditions
  • Your US state privacy rights
Springer Nature

© 2025 Springer Nature Limited