Abstract
Purpose
To directly compare the per-operative safety and efficacy of the 20- and 23-gauge vitrectomy systems as well as day 1 intraocular pressure (IOP).
Methods
Data were collected on 50 consecutive vitrectomy cases performed using the 20-gauge system and 23-gauge sutureless vitrectomy. All surgeries were carried out by one surgeon (RLB) at a single centre. Data collected prospectively included indication for surgery, iatrogenic retinal tears, and operating times.
Results
Most common indications for surgery were macular hole, rhegmatogenous retinal detachment, diabetic vitreous haemorrhage (no tractional retinal detachment), and macular pucker. Intraocular tamponade with air, sulphur hexafluoride (SF6), hexafluoroethane (C2F6) or octafluoropropane (C3F8), or silicone oil was used in 25 patients in the 20-gauge group and 46 patients in the 23-gauge group. One scleral port required suture in patients who underwent 23-gauge vitrectomy (0.67%). Every 20-gauge patient had all the three ports sutured. The mean first day IOP was 22.88 mm Hg in the 20-gauge vs 17.58 mm Hg in the 23-gauge (P<0.001). Four patients in the 20-gauge group had an IOP >40 mm Hg compared to none in the 23-gauge group. In contrast, four patients had postoperative hypotony in the 23-gauge group compared to none in the 20-gauge group. The mean operating time for all the 50 cases in each group was 39.4 (20 gauge) vs 29 min (23 gauge) P<0.001.
Conclusion
Our study indicates less risk of considerably raised IOPs and reduced surgical operating time with the 23-gauge system. Additional advantages observed included faster wound healing, diminished conjunctival scarring, improved patient comfort, and decreased postoperative inflammation.
Similar content being viewed by others
Log in or create a free account to read this content
Gain free access to this article, as well as selected content from this journal and more on nature.com
or
References
Machemer R, Buettner H, Norton EW, Parel JM . Vitrectomy: a pars plana approach. Trans Am Acad Ophthalmol Otolaryngol 1971; 75: 813–820.
Fujii GY, de Juan Jr E, Humayun MS, Pieramici DJ, Chang TS, Awh C et al. A new 25-gauge instrument system for transconjunctival sutureless vitrectomy surgery. Ophthalmology 2002; 109: 1807–1813.
Fujii GY, de Juan Jr E, Humayun MS, Chang TS, Pieramici DJ, Barnes A et al. Initial experience using the transconjunctival sutureless vitrectomy system for vitreoretinal surgery. Ophthalmology 2002; 109: 1814–1820.
Eckardt C . Transconjunctival sutureless 23-gauge vitrectomy. Retina 2005; 25: 208–211.
Soni M, McHugh D . 23-Gauge transconjunctival sutureless vitrectomy: a way forward. Eye News 2007; 14: 18–20.
Lakhanpal RR, Humayun MS, de Juan Jr E, Lim JI, Chong LP, Chang TS et al. Outcomes of 140 consecutive cases of 25-gauge transconjunctival surgery for posterior segment disease. Ophthalmology 2005; 112: 817–824.
Chen JC . Sutureless pars plana vitrectomy through self-sealing sclerotomies. Arch Ophthalmol 1996; 114: 1273–1275.
Jackson T . Modified sutureless sclerotomies in pars plana vitrectomy [letter]. Am J Ophthalmol 2000; 129: 116–117.
Milibak T, Suveges I . Complications of sutureless pars plana vitrectomy through self-sealing sclerotomies [letter]. Arch Ophthalmol 1998; 116: 119.
Misra A, Goble RR . Self-sealing sclerotomies in pars plana vitrectomy-a prospective evaluation of preoperative complications. Eye 2004; 18: 747–748.
Fine HF, Iranmanesh R, Iturralde D, Spaide RF . Outcomes of 77 consecutive cases of 23-gauge transconjunctival vitrectomy surgery for posterior segment disease. Ophthalmology 2007; 114: 1197–1200.
Chen E . 25-gauge transconjunctival sutureless vitrectomy. Curr Opin Ophthalmol 2007; 18: 188–193.
Author information
Authors and Affiliations
Corresponding author
Additional information
Disclosure
The Norfolk and Norwich University Hospital Trust was given an Oertli Novitrex vitrectomy machine in September 2006 to be a reference site as it was the first machine introduced into the United Kingdom. The authors have no financial or proprietary interest in the companies or products.
Rights and permissions
About this article
Cite this article
Misra, A., Ho-Yen, G. & Burton, R. 23-gauge sutureless vitrectomy and 20-gauge vitrectomy: a case series comparison. Eye 23, 1187–1191 (2009). https://doi.org/10.1038/eye.2008.175
Received:
Revised:
Accepted:
Published:
Issue date:
DOI: https://doi.org/10.1038/eye.2008.175
Keywords
This article is cited by
-
Twenty-seven-gauge vitrectomy: a consecutive, single-centre case series with exclusive use over a 4-year period
BMC Ophthalmology (2023)
-
25-Gauge-Makulachirurgie im Vergleich mit und ohne kombinierte Phakoemulsifikation und Kunstlinsenimplantation
Der Ophthalmologe (2022)
-
Endophthalmitis: Changes in Presentation, Management and the Role of Early Vitrectomy
Ophthalmology and Therapy (2021)
-
Intravitreal Aflibercept injection with Panretinal photocoagulation versus early Vitrectomy for diabetic vitreous hemorrhage: randomized clinical trial
BMC Ophthalmology (2020)
-
Iatrogenic retinal breaks and postoperative retinal detachments in microincision vitrectomy surgery compared with conventional 20-gauge vitrectomy: a meta-analysis
Eye (2019)


