Abstract
Aims:
To compare the efficacy of subthreshold diode laser photocoagulation with conventional threshold diode laser in clinically significant macular oedema (CSME) in diabetics.
Methods:
Prospective randomised controlled trial. Thirty eyes of 20 patients with CSME having central macular thickness (CMT) ⩾250 μm on optical coherence tomography (OCT) and best corrected Snellen visual acuity (BCVA) of 20/80 or better were randomly assigned to receive subthreshold diode laser (group A) or threshold laser (group B). The clinical course of BCVA, CMT on OCT, photo stress recovery time (PSRT), contrast sensitivity (CS) using Pelli Robson chart, and central visual field (10–2 VF, Humphrey Field Analyser II) were monitored regularly for 18 weeks after intervention.
Results:
Both groups showed significant (P=0.03) and comparable improvement in mean BCVA at 18 weeks visit. There were also significant and comparable reductions (P<0.01) in mean CMT at all visits compared with baseline in both groups. PSRT and CS (75±16 (mean±SD) and 0.72±0.3 in group A and 81±12 and 0.68±0.2 in group B pre-laser) were significantly better in group A at the final visit (66±17 and 1.04±0.3) as compared to group B (78±11 and 0.73±0.3). One patient in group B showed a paracentral scotoma on 10–2 VF after the laser, which persisted till the end of follow-up.
Conclusion:
Subthreshold diode laser photocoagulation is as effective as conventional threshold laser in reducing or eliminating diabetic macular oedema (on OCT) and in improving BCVA. Recovery of macular function as assessed by CS and PSRT maybe better with subthreshold laser.
Similar content being viewed by others
Log in or create a free account to read this content
Gain free access to this article, as well as selected content from this journal and more on nature.com
or
References
Moss SE, Klein R, Klein BE . The 14-year incidence of visual loss in a diabetic population. Ophthalmology 1998; 105: 998–1003.
Early Treatment Diabetic Retinopathy Study Research Group. ETDRS Report no 1. Photocoagulation for diabetic macular edema. Arch Ophthalmol 1985; 103: 1796–1806.
Olk RJ . Argon green versus krypton red modified grid laser photocoagulation for diffuse diabetic macular edema. Ophthalmology 1990; 97: 1101–1113.
Akduman L, Olk RJ . Diode laser versus argon green modified grid photocoagulation for diffuse diabetic macular edema. Ophthalmology 1997; 104: 1433–1441.
Early Treatment Diabetic Retinopathy Study Group. ETDRS Report no 12. Fundus photographic risk factors for progression of diabetic retinopathy. Ophthalmology 1991; 98: 823–833.
Schatz H, Madeira D, McDonald HR, Johnson RN . Progressive enlargement of laser scars following grid laser photocoagulation for diffuse macular edema. Arch Ophthalmol 1991; 109: 1549–1551.
Bresnik GH . Diabetic maculopathy: a critical review highlighting macular edema. Ophthalmology 1983; 90: 1301–1317.
Akduman L, Olk RJ . Sub threshold (invisible) modified grid diode laser photocoagulation in diffuse diabetic macular edema. Ophthalmic Surg Lasers 1999; 30: 706–714.
Olk RJ, Akduman L . Minimal intensity diode laser (810 nanometer) photocoagulation (MIP) for diffuse diabetic macular edema (DDME). Semin Ophthalmol 2000; 16: 25–30.
Glaser JS, Savino PJ, Sumers KD, McDonald SA, Knighton RW . The photo-stress recovery test in the clinical assessment of visual function. Am J Ophthalmol 1977; 83: 255–260.
Pelli DG, Robson JG, Wilkins AJ . The design of a new letter chart for measuring contrast sensitivity. Clin Vis Sci 1988; 2: 187–189.
Humphrey Instruments, Inc. Humphrey Field Analyzer II User's Guide. Humphrey Instruments Inc.: San Leandro, CA, 1994.
Caprioli J . Automated perimetry in glaucoma. In: Walsh TJ (ed). Visual Fields: Examination and Interpretation. American Academy of Ophthalmology: San Francisco, CA, 1990, pp 88.
Roider J . Laser treatment of retinal diseases by subthreshold laser effects. Semin Ophthalmol 1999; 14: 19–26.
Roider J, Brinkmann R, Wirbelauer C, Laqua H, Birngruber R . Subthreshold (retinal pigment epithelium) photocoagulation in macular diseases: a pilot study. Br J Ophthalmol 2000; 84: 40–47.
Tewari HK, Gupta V, Kumar A, Verma L . Efficacy of diode laser for managing diabetic macular oedema. Acta Ophthalmol Scand 1998; 76: 363–366.
Figueira J, Khan J, Nunes S, Sivaprasad S, Rosa A, Faria de Abreu J et al. Prospective randomized controlled trial comparing subthreshold micropulse diode laser photocoagulation and conventional green laser for clinically significant diabetic macular oedema. Br J Ophthalmol 2008; 93 (10): 1341–1344.
Laursen ML, Moeller F, Sander B, Sjoelie AK . Subthreshold micropulse diode laser treatment in diabetic macular ooedema. Br J Ophthalmol 2004; 88: 1173–1179.
Talwar D, Sharma N, Pai A, Azad RV, Kohli A, Virdi PS . Contrast sensitivity following focal laser photocoagulation in clinically significant macular oedema due to diabetic retinopathy. Clin Exp Ophthalmol 2001; 29: 17–21.
Bandello F, Polito A, Borrello MD, Zemella N, Isola M . ‘Light’ versus ‘classic’ laser treatment for clinically significant diabetic macular oedema. Br J Ophthalmol 2005; 89: 864–870.
Squirrell DM, Stewart AW, Joondeph BC, Danesh-Meyer HV, McGhee CN, Donaldson ML . Large-spot subthreshold infrared laser to treat diabetic macular edema. Retina 2008; 28: 615–621.
Acknowledgements
This work has been presented in part as a poster at the 2008 Joint annual meeting of American Academy of Ophthalmology and European Society of Ophthalmology (Atlanta, USA). Funding/support: none.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Competing interests
The authors declare no conflict of interest.
Rights and permissions
About this article
Cite this article
Kumar, V., Ghosh, B., Mehta, D. et al. Functional outcome of subthreshold versus threshold diode laser photocoagulation in diabetic macular oedema. Eye 24, 1459–1465 (2010). https://doi.org/10.1038/eye.2010.53
Received:
Revised:
Accepted:
Published:
Issue date:
DOI: https://doi.org/10.1038/eye.2010.53
Keywords
This article is cited by
-
Diabetic macular oedema and diode subthreshold micropulse laser (DIAMONDS): study protocol for a randomised controlled trial
Trials (2019)
-
How accurate is an LCD screen version of the Pelli–Robson test?
International Ophthalmology (2018)
-
Pathophysiology and treatment of diabetic retinopathy
Acta Diabetologica (2013)