Abstract
Purpose
To compare the diagnostic efficacy of wide-field digital retinal imaging (WFDRI) with binocular indirect ophthalmoscopy (BIO) for retinopathy of prematurity (ROP) screening.
Methods
Premature infants admitted for ROP screening were included in this prospective, randomized and double-blind comparative study. They were examined by using BIO and WFDRI.
Results
A total of 58 infants were enrolled in the study. The sensitivities of WFDRI in detecting any stage of ROP, treatment-requiring ROP and plus disease were 58.6, 100, and 100% respectively, with a specificity of 100% for all. The proportional agreement between WFDRI and BIO was 0.903 for detection of any stage of ROP, 1.0 for treatment-requiring ROP, and 1.0 for plus disease.
Conclusion
The sensitivity and specificity of WFDRI was excellent for the diagnosis of severe and treatment-requiring ROP. However, BIO was superior in mild ROP particularly for the ones in retinal periphery.
Similar content being viewed by others
Log in or create a free account to read this content
Gain free access to this article, as well as selected content from this journal and more on nature.com
or
References
Cryotherapy for Retinopathy of Prematurity Cooperative Group. Multicenter Trial of Cryotherapy for Retinopathy of Prematurity: ophthalmological outcomes at 10 years. Arch Ophthalmol 2001; 119: 1110–1118.
Early Treatment For Retinopathy Of Prematurity Cooperative Group. Revised indications for the treatment of retinopathy of prematurity: results of the Early Treatment for Retinopathy of Prematurity randomized trial. Arch Ophthalmol 2003; 121: 1684–1694.
Section on Ophthalmology American Academy of Pediatrics; American Academy of Ophthalmology; American Association for Pediatric Ophthalmology and Strabismus. Screening examination of premature infants for retinopathy of prematurity. Pediatrics 2006; 117: 572–576.
International Committee for the Classification of Retinopathy of Prematurity. The International Classification of Retinopathy of Prematurity revisited. Arch Ophthalmol 2005; 123: 991–999.
Gilbert C, Rahi J, Eckstein M, O'Sullivan J, Foster A . Retinopathy of prematurity in middle-income countries. Lancet 1997; 350: 12–14.
Schwartz SD, Harrison SA, Ferrone PJ, Trese MT . Telemedical evaluation and management of retinopathy of prematurity using a fiberoptic digital fundus camera. Ophthalmology 2000; 107: 25–28.
Wu C, Petersen RA, VanderVeen DK . RetCam imaging for retinopathy of prematurity screening. J AAPOS 2006; 10: 107–111.
Dai S, Chow K, Vincent A . Efficacy of wide-field digital retinal imaging for retinopathy of prematurity screening. Clin Exp Ophthalmol 2011; 39: 23–29.
Dhaliwal C, Wright E, Graham C, McIntosh N, Fleck BW . Wide-field digital retinal imaging versus binocular indirect ophthalmoscopy for retinopathy of prematurity screening: a two-observer prospective, randomised comparison. Br J Ophthalmol 2009; 93: 355–359.
Laws DE, Morton C, Weindling M, Clark D . Systemic effects of screening for retinopathy of prematurity. Br J Ophthalmol 1996; 80: 425–428.
Mavrofrides EC, Berrocal AM, Murray TG . Development of multiple subretinal hemorrhages during diode laser supplementation for retinopathy of prematurity. J Pediatr Ophthalmol Strabismus 2006; 43: 110–113.
Richter GM, Williams SL, Starren J, Flynn JT, Chiang MF . Telemedicine for retinopathy of prematurity diagnosis: evaluation and challenges. Surv Ophthalmol 2009; 54: 671–685.
Adams GG, Clark BJ, Fang S, Hill M . Retinal haemorrhages in an infant following RetCam screening for retinopathy of prematurity. Eye (Lond) 2004; 18: 652–653.
Trese MT . What is the real gold standard for ROP screening? Retina 2008; 28: S1–S2.
Acknowledgements
The study was conducted in Etlik Zubeyde Hanim Maternity and Women’s Health Research Hospital, Department of Ophthalmology, Ankara, Turkey.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Competing interests
The authors declare no conflict of interest.
Rights and permissions
About this article
Cite this article
Sekeroglu, M., Hekimoglu, E., Sekeroglu, H. et al. Alternative methods for the screening of retinopathy of prematurity: binocular indirect ophthalmoscopy vs wide-field digital retinal imaging. Eye 27, 1053–1057 (2013). https://doi.org/10.1038/eye.2013.128
Received:
Accepted:
Published:
Issue date:
DOI: https://doi.org/10.1038/eye.2013.128
Keywords
This article is cited by
-
Diagnostic Accuracy of Pediatrician-performed Digital Retinal Imaging with 3nethra neo for ROP Screening
Indian Journal of Pediatrics (2024)
-
Retinopathy of prematurity detection: a retrospective quality improvement project before-after implementation of retinal digital imaging for screening
European Journal of Pediatrics (2023)
-
Neonatal eye screening for 203 healthy term new-borns using a wide-field digital retinal imaging system
BMC Ophthalmology (2021)


