Abstract
Aims
To evaluate the technique of eye drop instillation in patients with glaucoma and assess factors associated with a good technique.
Methods
A cross-sectional observational study of 85 participants using self-administered topical medication for glaucoma or ocular hypertension. Patients were asked to demonstrate how they normally instil eye drops using a 5-ml bottle of sterile artificial tear solution. The procedure was recorded and assessed by two masked graders. Whether the patient had been previously shown how to instil drops, the number of eye medications used, and self-perceived difficulty of using drops were also recorded. Univariable logistic regression was performed to relate each variable to drop technique and variables with P<0.2 were included in a multivariable logistic regression analysis.
Results
54.1% (46/85) of patients had a poor drop technique, 11.8% (10/85) missed the eye, 15.3% (13/85) touched the tip of the bottle to the bulbar conjunctiva or cornea, and 27.1% (23/85) touched the eyelid or lashes with the bottle tip. 81.2% (69/85) could not recall being shown how to instil eye drops. In the multivariable model, previous instruction regarding drop instillation technique was significantly associated with good technique (adjusted OR=8.17, 95% CI 2.02–33.05, P=0.003) and increasing age was associated with poor technique (adjusted OR=0.95, 95% CI 0.91–0.99, P=0.017).
Conclusions
Education relating to eye drop instillation technique is significantly associated with a patient's ability to instil drops correctly. The assessment of a patient’s ability to instil eye drops correctly should be a routine part of the glaucoma examination.
Similar content being viewed by others
Log in or create a free account to read this content
Gain free access to this article, as well as selected content from this journal and more on nature.com
or
References
Kass MA, Meltzer DW, Gordon M, Cooper D, Goldberg J . Compliance with topical pilocarpine treatment. Am J Ophthalmol 1986; 101: 515–523.
Winfield AJ, Jessiman D, Williams A, Esakowitz L . A study of the causes of non-compliance by patients prescribed eyedrops. Br J Ophthalmol 1990; 74: 477–480.
Granström PA . Glaucoma patients not compliant with their drug therapy: clinical and behavioural aspects. Br J Ophthalmol 1982; 66: 464–470.
Lu VH, Goldberg I, Lu CY . Use of glaucoma medications: state of the science and directions for observational research. Am J Ophthalmol 2010; 150: 569–574.
Stryker JE, Beck AD, Primo SA, Echt KV, Bundy L, Pretorius GC et al. An exploratory study of factors influencing glaucoma treatment adherence. J Glaucoma 2010; 19: 66–72.
Tsai JC, McClure CA, Ramos SE, Schlundt DG, Pichert JW . Compliance barriers in glaucoma: a systematic classification. J Glaucoma. 2003; 12: 393–398.
Sleath B, Blalock S, Covert D, Stone JL, Skinner AC, Muir K et al. The relationship between glaucoma medication adherence, eye drop technique, and visual field defect severity. Ophthalmology 2011; 118: 2398–2402.
Kass MA, Hodapp E, Gordon M, Kolker AE, Goldberg I . Part I. Patient administration of eyedrops: interview. Ann Ophthalmol 1982; 14: 775–779.
Fraunfelder FT . Extraocular fluid dynamics: how best to apply topical ocular medication. Trans Am Ophthalmol Soc 1976; 74: 457–487.
Zimmerman TJ, Kooner KS, Kandarakis AS, Ziegler LP . Improving the therapeutic index of topically applied ocular drugs. Arch Ophthalmol 1984; 102: 551–553.
Tsai T, Robin AL, Smith JP III . An evaluation of how glaucoma patients use topical medications: a pilot study. Trans Am Ophthalmol Soc 2007; 105: 29–35.
Geyer O, Bottone EJ, Podos SM, Schumer RA, Asbell PA . Microbial contamination of medications used to treat glaucoma. Br J Ophthalmol 1995; 79: 376–379.
Brown MM, Brown GC, Spaeth GL . Improper topical self-administration of ocular medication among patients with glaucoma. Can J Ophthalmol 1984; 19: 2–5.
Gupta R, Patil B, Shah BM, Bali SJ, Mishra SK, Dada T . Evaluating eye drop instillation technique in glaucoma patients. J Glaucoma 2012; 21: 189–192.
Kholdebarin R, Campbell RJ, Jin YP, Buys YM . Multicenter study of compliance and drop administration in glaucoma. Can J Ophthalmol 2008; 43: 454–461.
Dietlein TS, Jordan JF, Lüke C, Schild A, Dinslage S, Krieglstein GK . Self-application of single-use eyedrop containers in an elderly population: comparisons with standard eyedrop bottle and with younger patients. Acta Ophthalmol 2008; 86: 856–859.
Cohen J . Weighted kappa: nominal scale agreement provision for scaled disagreement or partial credit. Psychol Bull 1968; 70: 213–220.
Landis JR, Koch GG . The measurement of observer agreement for categorical data. Biometrics 1977; 33: 159–174.
Kim MS, Choi CY, Kim JM, Woo HY . Microbial contamination of multiply used preservative-free artificial tears packed in reclosable containers. Br J Ophthalmol 2008; 92: 1518–1521.
Schein OD, Wasson PJ, Boruchoff SA, Kenyon KR . Microbial keratitis associated with contaminated ocular medications. Am J Ophthalmol 1988; 15 (105): 361–365.
Stone JL, Robin AL, Novack GD, Covert DW, Cagle GD . An objective evaluation of eyedrop instillation in patients with glaucoma. Arch Ophthalmol 2009; 127: 732–736.
Nordmann JP, Baudouin C, Bron A, Denis P, Rouland JF, Sellem E et al. Xal-Ease: impact of an ocular hypotensive delivery device on ease of eyedrop administration, patient compliance, and satisfaction. Eur J Ophthalmol 2009; 19: 949–956.
Salyani A, Birt C . Evaluation of an eye drop guide to aid self-administration by patients experienced with topical use of glaucoma medication. Can J Ophthalmol 2005; 40: 170–174.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Competing interests
The authors declare no conflict of interest.
Rights and permissions
About this article
Cite this article
Tatham, A., Sarodia, U., Gatrad, F. et al. Eye drop instillation technique in patients with glaucoma. Eye 27, 1293–1298 (2013). https://doi.org/10.1038/eye.2013.187
Received:
Accepted:
Published:
Issue date:
DOI: https://doi.org/10.1038/eye.2013.187
Keywords
This article is cited by
-
Factors Associated with Topical Medication Instillation Failure in Glaucoma: VRAMS-QPiG Study
Advances in Therapy (2023)
-
Challenging the "Topical Medications-First” Approach to Glaucoma: A Treatment Paradigm in Evolution
Ophthalmology and Therapy (2023)
-
Assessment of eye drop instillation techniques among patients with primary open angle glaucoma in a Nigerian tertiary hospital
International Ophthalmology (2022)
-
Liposomal drug delivery system for anti-inflammatory treatment after cataract surgery: a phase I/II clinical trial
Drug Delivery and Translational Research (2022)
-
Ciprofloxacin self-dissolvable Soluplus based polymeric films: a novel proposal to improve the management of eye infections
Drug Delivery and Translational Research (2021)