Abstract
Purpose
To determine whether the ratio of optic disk diameter to disk-to-macula distance (DD/DM) in children with optic nerve hypoplasia (ONH) changes over time.
Patients and methods
Fifteen subjects (29 eyes) enrolled in a prospective registry study on ONH had fundus photography performed under the age of 24 months and again at 60 months. Using the ratio of the DD/DM method, the relative size of the optic disk was assessed twice for each photo by one masked expert examiner to determine whether any change in relative disk size occurred over time.
Results
There was no change in relative optic disk size between initial and final fundus photographs. The average (±SD) age at the time of initial and final fundus photography was, respectively, 11.6±5.2 months and 60.6±1.3 months. Strong concordance was noted between the average DD/DM of the initial and the final photographs (ρ=0.939; 95% CI: 0.893, 0.981). There was negligible difference between the individual time point measurements (−0.011±0.03) (95% LOA: −0.07, 0.04).
Conclusion
There were no clinically significant changes in relative optic disk size over time in children with ONH; thus, DD/DM measurements need not be adjusted by age beyond 1 year in children with this disorder.
Similar content being viewed by others
Log in or create a free account to read this content
Gain free access to this article, as well as selected content from this journal and more on nature.com
or
References
Patel L, McNally RJQ, Harrison E, Lloyd IC, Clayton PE . Geographical distribution of optic nerve hypoplasia and septo-optic dysplasia in northwest England. J Pediatr 2006; 148 (1): 85–88.
Garcia-Filion P, Epport K, Nelson M, Azen C, Geffner ME, Fink C et al. Neuroradiographic, endocrinologic, and ophthalmic correlates of adverse developmental outcomes in children with optic nerve hypoplasia: a prospective study. Pediatrics 2008; 121 (3): e653–e659.
Ahmad T, Garcia-Filion P, Borchert M, Kaufman F, Burkett L, Geffner M . Endocrinological and auxological abnormalities in children with optic nerve hypoplasia: a prospective study. J Pediatr 2006; 148 (1): 78–84.
Borchert M, Garcia-Filion P . The syndrome of optic nerve hypoplasia. Curr Neurol Neurosci Rep 2008; 8 (5): 395–403.
Borchert M, McCulloch D, Rother C, Stout AU . Clinical assessment, optic disk measurements, and visual-evoked potential in optic nerve hypoplasia. Am J Ophthalmol 1995; 120 (5): 605–612.
De Silva DJ, Cocker KD, Lau G, Clay ST, Fielder AR, Moseley MJ . Optic disk size and optic disk-to-fovea distance in preterm and full-term infants. Invest Ophthalmol Vis Sci 2006; 47: 4683–4686.
Eustis H, Sprague M, Guthrie E . Postnatal development. In: Wright KW, Spiegel PH (eds). Pediatric Ophthalmology and Strabismus. Springer-Verlag: New York, USA, 2003 pp 39–41.
Rimmer S, Keating C, Chou T, Farb MD, Christenson PD, Foos RY et al. Growth of the human optic disk and nerve during gestation, childhood, and early adulthood. Am J Ophthalmol 1993; 16: 748–753.
Barr DB, Weir CR, Purdie AT . An appraisal of the disc-macula distance to disc diameter ratio in the assessment of optic disc size. Ophthalmic Physiol Opt 1999; 19 (5): 365–375.
Alvarez E, Wakakura M, Khan Z, Dutton GN . The disc-macula distance to disc diameter ratio: a new test for confirming optic nerve hypoplasia in young children. J Pediatr Ophthalmol Strabismus 1988; 25 (3): 151–154.
Zeki SM, Dutton GN . Optic nerve hypoplasia in children. Br J Ophthalmol 1990; 74: 300–304.
Borchert MS, McCulloch DL, Rother C, Stout AU . Clinical assessment, optic disk measurements, and visual-evoked potential in optic nerve hypoplasia. Am J Ophthalmol 1995; 120: 605–612.
Lin LI . A concordance correlation coefficient to evaluate reproducibility. Biometrics 1989; 45: 255–268.
Bland JM, Altman DG . Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; 1: 307–310.
Garcia-Filion P, Fink C, Geffner ME, Borchert M . Optic nerve hypoplasia in North America: a re-appraisal of perinatal risk factors. Acta Ophthalmolol 2010; 88 (5): 527–534.
Kandasamy Y, Smith R, Wright IMR, Hartley L . Optic disc measurements in full term infants. Br J Ophthalmol 2012; 96: 662–664.
Bengtsson B, Krakau CE . Some essential optical features of the Zeiss fundus camera. Acta Ophthalmol (Copenh) 1977; 55: 123–131.
Acknowledgements
This research was supported in part by the One Small Voice Foundation and Grant No. UL1TR000130, Children’s Hospital Los Angeles from the National Center for Advancing Translational Sciences (NCATS) at the National Institute of Health.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Competing interests
The authors declare no conflict of interest.
Rights and permissions
About this article
Cite this article
Sutedja, J., Garcia-Filion, P., Fink, C. et al. Absence of age-related optic disk changes in young children with optic nerve hypoplasia. Eye 28, 562–566 (2014). https://doi.org/10.1038/eye.2014.12
Received:
Accepted:
Published:
Issue date:
DOI: https://doi.org/10.1038/eye.2014.12