Supplementary Figure 4: Calibration curve to determine the fluorescence level in cell lysates described in Step 7. | Nature Protocols

Supplementary Figure 4: Calibration curve to determine the fluorescence level in cell lysates described in Step 7.

From: Real-time single-molecule coimmunoprecipitation of weak protein-protein interactions

Supplementary Figure 4

Shown are 11 different concentrations of recombinant EGFP or mCherry used to measure fluorescence intensity. We plot the fluorescence intensity versus protein concentration and fit the data to a linear function to obtain the calibration curve. This calibration curve converts the fluorescence intensity observed to the concentration of EGFP or mCherry-labelled proteins in cell lysates. (a) Exemplary calibration curve of recombinant EGFP. (b) Exemplary calibration curve of recombinant mCherry.

Back to article page