Abstract
Purpose
To assess the incidence of iatrogenic retinal breaks (IRBs) and postoperative retinal detachments (RDs) in microincision vitrectomy surgery (MIVS) compared with 20-gauge (20 G) vitrectomy.
Methods
A comprehensive literature search was performed to find relevant studies and a meta-analysis of the IRBs and postoperative RDs rates after 20 G vitrectomy versus MIVS was conducted.
Results
Thirty-two studies were selected, including 14,373 eyes (6932 eyes in the 20 G group, 7441 eyes in the MIVS group). The meta-analysis demonstrated that the incidence of IRBs was significantly higher in 20 G vitrectomy vs. MIVS (OR = 2.22, 95% CI, 1.93−2.57, P < 0.00001) and in a subanalysis vs. 23 G MIVS (OR = 2.19, 95% CI, 1.87−2.56, P < 0.00001) and vs. 25 G MIVS (OR = 2.27, 95% CI, 1.62−3.18, P < 0.00001). Similar result was obtained in a subanalysis for macular surgery (OR = 2.44, 95% CI, 1.99−2.99, P < 0.00001), and also for sclerotomy-related IRBs (OR = 3.73, 95% CI, 2.55−5.44, P < 0.00001), but not for surgically induced posterior vitreous detachment-related IRBs (OR = 1.59, 95% CI, 0.89−2.84, P = 0.12). The incidence of postoperative RDs in 20 G vitrectomy was significantly higher compared to MIVS (OR = 1.72, 95% CI, 1.21−2.46, P = 0.003) and in a subanalysis vs. 23 G MIVS (OR = 2.45, 95% CI, 1.50−4.00, P = 0.0003), but not for 25 G MIVS (OR = 1.01, 95% CI, 0.63−1.64, P = 0.96). Similar result was obtained in a subanalysis for macular surgery (OR = 1.89, 95% CI, 1.26−2.85, P = 0.002).
Conclusion
This meta-analysis demonstrated that MIVS is associated with a lower risk of IRBs and postoperative RDs compared to 20 G vitrectomy.
Similar content being viewed by others
Log in or create a free account to read this content
Gain free access to this article, as well as selected content from this journal and more on nature.com
or
References
O’Malley C, Heintz RM, Sr. Vitrectomy with an alternative instrument system. Ann Ophthalmol. 1975;7:585–8.591-4.
Zhang ZH, Liu HY, Wimpissinger B, Avitabile T, Xu X, Liu K. Transconjunctival sutureless vitrectomy versus 20-gauge vitrectomy for vitreoretinal surgery: a meta-analysis of randomized controlled trials. Graefes Arch Clin Exp Ophthalmol. 2013;251:681–8.
Chen G, Tzekov R, Li W, Jiang F, Mao S, Tong Y. Incidence of endophthalmitis after vitrectomy: a systematic review and meta-analysis. Retina. 2018. https://doi.org/10.1097/IAE.0000000000002055. e-pub ahead of print. 23 January 2018
Moore JK, Kitchens JW, Smiddy WE, Mavrofrides EC, Gregorio G. Retinal breaks observed during pars plana vitrectomy. Am J Ophthalmol. 2007;144:32–36.
Covert DJ, Henry CR, Bhatia SK, Croskrey J, Sanchez CR, Han DP. Intraoperative retinal tear formation and postoperative rhegmatogenous retinal detachment in transconjunctival cannulated vitrectomy systems compared with the standard 20-gauge system. Arch Ophthalmol. 2012;130:186–9.
Gosse E, Newsom R, Lochhead J. The incidence and distribution of iatrogenic retinal tears in 20-gauge and 23-gauge vitrectomy. Eye (Lond). 2012;26:140–3.
Hikichi T, Matsumoto N, Ohtsuka H, Higuchi M, Matsushita T, Ariga H, et al. Comparison of one-year outcomes between 23- and 20-gauge vitrectomy for preretinal membrane. Am J Ophthalmol. 2009;147:639–43.
Haas A, seidel G, Steinbrugger I, Maier R, Gasser-Steiner V, Wedrich A, et al. Twenty-three-gauge and 20-gauge vitrectomy in epiretinal membrane surgery. Retina. 2010;30:112–6.
Hikichi T, Kosaka S, Takami K, Ariga H, Ohtsuka H, Higuchi M, et al. 23- and 20-gauge vitrectomy with air tamponade with combined phacoemulsification for idiopathic macular hole: a single-surgeon study. Am J Ophthalmol. 2011;152:114–21.
Hikichi T, Kosaka S, Takami K, Ariga H, Ohtsuka H, Higuchi M, et al. Incidence of retinal breaks in eyes undergoing 23-gauge or 20-gauge vitrectomy with induction of posterior vitreous detachment. Retina. 2012;32:1100–5.
Pielen A, Guerra NI, Bohringer D, Junker B, Bühler AD, Stahl A, et al. Intra- and postoperative risks and complications of small-gauge (23-G) versus conventional (20-G) vitrectomy for macular surgery. Eur J Ophthalmol. 2014;24:778–85.
Le Rouic JF, Becquet F, Ducournau D. Does 23-gauge sutureless vitrectomy modify the risk of postoperative retinal detachment after macular surgery? A comparison with 20-gauge vitrectomy. Retina. 2011;31:902–8.
Sandali O, EI Sanharawi M, Lecuen N, Barale PO, Bonnel S, Basli E, et al. 25-, 23-, and 20-gauge vitrectomy in epiretinal membrane surgery: a comparattive study of 553 cases. Graefes Arch Clin Exp Ophthalmol. 2011;249:1811–9.
Rizzo S, Belting C, Genovesi-Ebert F, di Bartolo E. Incidence of retinal detachment after small-incision, sutureless pars plana vitrectomy compared with conventional 20-gauge vitrectomy in macular hole and epiretinal membrane surgery. Retina. 2010;30:1065–71.
Stang A. Critical evaluation of the Newcastle-Ottawa scale for the assessment of the quality of nonrandomized studies in meta-analyses. Eur J Epidemiol. 2010;25:603–5.
Jadad AR, Moore RA, Carroll D, Jenkinson C, Reynolds DJ, Gavaghan DJ, et al. Assessing the quality of reports of randomized clinical trials: is blinding necessary? Control Clin Trials. 1996;17:1–12.
Lau J, Ioannidis JP, Schmid CH. Quantitative synthesis in systematic reviews. Ann Intern Med. 1997;127:820–6.
Begg CB, Mazumdar M. Operating characteristics of a rank correlation test for publication bias. Biometrics. 1994;50:1088–101.
Egger M, Smith GD, Schneider M, Minder C. Bias in meta-analysis detected by a simple, graphical test. BMJ. 1997;315:629–34.
Albrieux M, Rouberol F, Bernheim D, Romanet JP, Chiquet C. Comparative study of 23-gauge vitrectomy versus 20-gauge vitrectomy for the treatment of rhegmatogenous retinal detachment. Graefes Arch Clin Exp Ophthalmol. 2011;249:1459–68.
Cha DM, Woo SJ, Park KH, Chung H. Intraoperative iatrogenic peripheral retinal break in 23-gauge transconjunctival sutureless vitrectomy versus 20-gauge conventional vitrectomy. Graefes Arch Clin Exp Ophthalmol. 2013;251:1469–74.
Misra A, Ho-Yen G, Burton RL. 23-gauge sutureless vitrectomy and 20-gauge vitrectomy: a case series comparison. Eye (Lond). 2009;23:1187–91.
Park DH, Shin JP, Kim SY. Comparsion of clinical outcomes between 23-gauge and 20-gauge vitrectomy in patients with proliferative diabetic retinopathy. Retina. 2010;30:1662–70.
Dihowm F, MacCumber M. Comparison of outcomes between 20, 23 and 25 gauge vitrectomy for idiopathic macular hole. Int J Retin Vitr. 2015;1:6. eCollection 2015
Goncu T, Gurelik G, Hasanreisoglu B. Comparison of efficacy and safety between transconjunctival 23-gauge and conventional 20-gauge vitrectomy systems in macular surgery. Korean J Ophthalmol. 2012;26:339–46.
Jalil A, Ho WO, Charles S, Dhawahir-Scala F, Patton N. Iatrogenic retinal breaks in 20-G versus 23-G pars plana vitrectomy. Graefes Arch Clin Exp Ophthalmol. 2013;251:1463–7.
Issa SA, Connor A, Habib M, Steel DH. Comparison of retinal breaks observed during 23 gauge transconjunctival vitrectomy versus conventional 20 gauge surgery for proliferative diabetic retinopathy. Clin Ophthalmol. 2011;5:109–14.
Krishnan R, Tossounis C, Fung Yang Y. 20-gauge and 23-gauge phacovitrectomy for idiopathic macular holes: comparision of complications and long-term outcomes. Eye (Lond). 2013;27:72–77.
Nakano T, Uemura A, Sakamoto T. Incidence of iatrogenic peripheral retinal breaks in 23-gauge vitrectomy for macular diseases. Retina. 2011;31:1997–2001.
Nagpal M, Wartikar S, Nagpal K. Comparison of clinical outcomes and wound dynamics of sclerotomy ports of 20, 25, and 23 gauge vitrectomy. Retina. 2009;29:225–31.
Neffendorf JE, Gupta B, Williamson TH. Intraoperative complications of patients undergoing small-gauge and 20-gauge vitrectomy: a database study of 4,274 procedures. Eur J Ophthalmol. 2017;27:226–30.
Neuhann IM, Hilgers RD, Bartz-Schmidt KU. Intraoperative retinal break formation in 23-/25-gauge vitrectomy versus 20-gauge vitrectomy. Ophthalmologica. 2013;229:50–53.
Scartozzi R, Bessa AS, Gupta OP, Regillo CD. Intraoperative sclerotomy-related retinal breaks for macular surgery, 20- vs 25-gauge vitrectomy systems. Am J Ophthalmol. 2007;143:155–6.
Shinoda H, Shinoda K, Satofuka S, Imamura Y, Ozawa Y, Ishida S, et al. Visual recovery after vitrectomy for macular hole using 25-gauge instruments. Acta Ophthalmol. 2008;86:151–5.
Tan HS, Mura M, Lesnik Oberstein SY, Bijl HM. Safety of vitrectomy for floaters. Am J Ophthalmol. 2011;151:995–8.
Tosi GM, Esposti P, Romeo N, Marigliani D, Cevenini G, Massimo P, et al. The incidence of rhegmatogenous retinal complications in macular surgery after prophylactic preoperative laser retinopexy: a retrospective study. Med (Baltim). 2016;95:e3283.
Valmaggia. Pars plana vitrectomy with 25-gauge instruments in the treatment of idiopathic epiretinal membranes. Klin Monbl Augenheilkd. 2007;224:292–6.
Wickham L, Bunce C, Kwan AS, Bainbridge J, Aylward GW. A pilot randomised controlled trial comparing the postoperative pain experience following vitrectomy with a 20-gauge system and the 25-gauge transconjunctival system. Br J Ophthalmol. 2010;94:36–40.
Wimpissinger B, Kellner L, Brannath W, Krepler K, Stolba U, Mihalics C, et al. 23-gauge versus 20-gauge system for pars plana vitrectomy: a prospective randomised clinical trial. Br J Ophthalmol. 2008;92:1483–7.
Yokota R, Inoue M, Itoh Y, Rii T, Hirota K, Hirakata A. Comparison of microinsicion vitrectomy and conventional 20-gauge vitrectomy for severe proliferative diabetic retinopathy. Jpn J Ophthalmol. 2015;59:288–94.
Zhang J, Li Y, Zhao X, Yu X, Lu L. Comparison of clinical features after 20-gauge vitrectomy versus 23-gauge vitrectomy. Asia Pac J Ophthalmol (Phila). 2015;4:367–70.
Fang Y, Ku H, Liu Y, Gan D. Trends in the characteristics of vitrectomy in Eastern China. Clin Ophthalmol. 2018;12:1993–2000.
Fischer CV, Kulanga M, Hoerauf H. Trends in retinal detachment surgery: what has changed compared to 2001? Ophthalmologe. 2018;115:663–8.
Tayyab H, Khan AA, Sadiq MAA, Karamat I. Comparison of 23 gauge transconjunctival releasable suture vitrectomy with standard 20 gauge vitrectomy. Pak J Med Sci. 2018;34:328–32.
Ghasemi FK, Shaheen Y, Karimi MA, Aghaei H, Parvaresh MM, Bahmani KM, et al. Schirmer test changes after 20 gauge and 23 gauge pars plana vitrectomy. Rom J Ophthalmol. 2017;61:39–43.
Sjaarda RN, Glaser BM, Thompson JT, Murphy RP, Hanham A. Distribution of iatrogenic retinal breaks in macular hole surgery. Ophthalmology. 1995;102:1387–92.
Tan HS, Oberstein SYL, Mura M, de Smet M. Enhanced internal research for iatrogenic retinal breaks in 20-gauge macular surgery. Br J Ophthalmol. 2010;94:1490–2.
Chung SE, Kim KY, Kang SW. Retinal breaks associated with the induction of posterior vitreous detachment. Am J Ophthalmol. 2009;147:1012–6.
Mura M, Barca F, Dell’Omo R, Nasini F, Peiretti E. Iatrogenic retinal breaks in ultrahigh-speed 25-gauge vitrectomy: a prospective study of elective cases. Br J Ophthalmol. 2016;100:1383–7.
Teixeira A, Chong LP, Matsuoka N, Arana L, Kerns R, Bhadri P, et al. Vitreoretinal traction created by conventional cutters during vitrectomy. Ophthalmology. 2010;117:1387–92.
Abulon DJ. Vitreous flow rates through dual pneumatic cutters: effects of duty cycle and cut rate. Clin Ophthalmol. 2015;9:253–61.
Rizzo S, Belting C, Genovesi-Ebert F. Retinal detachment after small-incision, sutureless pars plana vitrectomy: possible causative agents. Graefes Arch Clin Exp Ophthalmol. 2010;248:1401–6.
Acknowledgements
Funding
This work was supported by the National Natural Science Foundation of China (No. 81570875 to WSL), Welfare Technology Applied Research Program Fund of Science Technology Department of Zhejiang Province (No. LGF18H120002 to YHT) and Quzhou Science and Technology Project (No. 20172041 to GHC).
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
The authors declare that they have no conflict of interest.
Supplementary information
Rights and permissions
About this article
Cite this article
Chen, G.H., Tzekov, R., Jiang, F.Z. et al. Iatrogenic retinal breaks and postoperative retinal detachments in microincision vitrectomy surgery compared with conventional 20-gauge vitrectomy: a meta-analysis. Eye 33, 785–795 (2019). https://doi.org/10.1038/s41433-018-0319-5
Received:
Revised:
Accepted:
Published:
Issue date:
DOI: https://doi.org/10.1038/s41433-018-0319-5
This article is cited by
-
Internal 40-gauge microneedle drainage for the management of subretinal fluid in rhegmatogenous retinal detachment surgery
International Journal of Retina and Vitreous (2025)
-
Advancements in robotic surgery for vitreoretinal diseases: current trends and the future
Japanese Journal of Ophthalmology (2025)
-
Factors affecting anatomical and visual outcomes in Terson syndrome managed by surgery or observation
Eye (2024)
-
Pars plana vitrectomy in patients aged 85 years and older: a single-centre, retrospective cohort study
International Ophthalmology (2023)
-
3D Visualization System-Assisted Vitrectomy for Rhegmatogenous Retinal Detachment: Leave Out the Perfluorocarbon Liquid