Abstract
Objective
This study aims to evaluate the photoreceptor outer segment (PROS) length in patients who use hydroxychloroquine (HCQ) prior to the development of retinopathy.
Methods
In this prospective, single-centre, comparative study, 44 patients using HCQ for ≥5 years, 30 patients using HCQ <5 years, and 45 age- and sex-matched healthy controls were enrolled. The participants underwent a detailed ophthalmologic examination, spectral-domain optical coherence tomography (SD-OCT) imaging, and 10–2 automated visual field testing. The PROS length was defined as the distance between the inner surface of the ellipsoid zone and the inner surface of the retina pigment epithelium. The measurements were performed subfoveally and at 500–1000–1500 µm temporally and nasally to the foveola.
Results
The mean PROS length of long-term users (≥5 years) was statistically greater than the controls at all measurement points (p < 0.001 at all points). Although the subfoveal PROS length was comparable between the long-term and short-term users (p = 0.148), the parafoveal PROS length measurements (nasal 1500 µm, nasal 1000 µm, nasal 500 µm, temporal 1000 µm, and temporal 1500 µm) of the long-term users were significantly greater than those of the short-term users (p < 0.001, p = 0.002, p = 0.027, p = 0.018, p = 0.001, respectively). No significant difference was found between the short-term users and the controls (p = 0.815, p = 0.395, p = 0.093, p = 0.079, p = 0.133, p = 0.686, p = 0.341, respectively).
Conclusion
The PROS length was greater in patients who used HCQ ≥5 years. Possible retinal pigment epithelium toxicity may have caused this finding.
Similar content being viewed by others
Log in or create a free account to read this content
Gain free access to this article, as well as selected content from this journal and more on nature.com
or
References
Marmor MF, Kellner U, Lai TY, Melles RB, Mieler WF, American Academy of Ophthalmology. Recommendations on screening for chloroquine and hydroxychloroquine retinopathy [2016 Revision]. Ophthalmology. 2016;123:1386–94.
Melles RB, Marmor MF. The risk of toxic retinopathy in patients on long-term hydroxychloroquine therapy. JAMA Ophthalmol. 2014;132:1453–60.
Marmor MF, Kellner U, Lai TY, Lyons JS, Mieler WF, American Academy of Ophthalmology. Revised recommendations on screening for chloroquine and hydroxychloroquine retinopathy. Ophthalmology. 2011;118:415–22.
Wolfe F, Marmor MF. Rates and predictors of hydroxychloroquine retinal toxicity in patients with rheumatoid arthritis and systemic lupus erythematosus. Arthritis Care Res [Hoboken]. 2010;62:775–84.
Lally DR, Heier JS, Baumal C, Witkin AJ, Maler S, Shah CP, et al. Expanded spectral domain-OCT findings in the early detection of hydroxychloroquine retinopathy and changes following drug cessation. Int J Retina Vitreous. 2016;18:18.
Marmor MF, Hu J. Effect of disease stage on progression of hydroxychloroquine retinopathy. JAMA Ophthalmol. 2014;132:1105–12.
Marmor MF. Comparison of screening procedures in hydroxychloroquine toxicity. Arch Ophthalmol. 2012;130:461–9.
Cukras C, Huynh N, Vitale S, Wong WT, Ferris FL 3rd, Sieving PA. Subjective and objective screening tests for hydroxychloroquine toxicity. Ophthalmology. 2015;122:356–66.
de Sisternes L, Hu J, Rubin DL, Marmor MF. Analysis of inner and outer retinal thickness in patients using hydroxychloroquine prior to development of retinopathy. JAMA Ophthalmol. 2016. https://doi.org/10.1001/jamaophthalmol.2016.0155
Uslu H, Gurler B, Yildirm A, Tatar MG, Aylin Kantarci F, Goker H, et al. Effect of hydroxychloroquine on the retinal layers: a quantitative evaluation with spectral-domain optical coherence tomography. J Ophthalmol. 2016. https://doi.org/10.1155/2016/8643174.
Rosenthal A, Kolb H, Bergsma D, Huxsoll D, Hopkins JL. Chloroquine retinopathy in the rhesus monkey. Invest Ophthalmol Vis Sci. 1978;17:1158–75.
Mahon GJ, Anderson HR, Gardiner TA, McFarlane S, Archer DB, Stitt AW. Chloroquine causes lysosomal dysfunction in neural retina and RPE: implications for retinopathy. Curr Eye Res. 2004;28:277–84.
Stepien KE, Han DP, Schell J, Godara P, Rha J, Carroll J. Spectral-domain optical coherence tomography and adaptive optics may detect hydroxychloroquine retinal toxicity before symptomatic vision loss. Trans Am Ophthalmol Soc. 2009;107:28–33.
Debellemaniere G, Flores M, Tumahai P, Meillat M, Bidaut Garnier M, Delbosc B, et al. Assessment of parafoveal cone density in patients taking hydroxychloroquine in the absence of clinically documented retinal toxicity. Acta Ophthalmol. 2015;93:534–40.
Pasadhika S, Fishman GA, Choi D, Shahidi M. Selective thinning of the perifoveal inner retina as an early sign of hydroxychloroquine retinal toxicity. Eye [Lond].. 2010;24:756–62.
Modi YS, Au A, Parikh VS, Ehlers JP, Schachat AP, Singh RP. Volumetric single-layer inner retinal analysis in patients with hydroxychloroquine toxicity. Retina. 2016;36:1941–50.
Yülek F, Uğurlu N, Akçay E, Kocamış Sİ, Gerçeker S, Erten Ş, et al. Early retinal and retinal nerve fiber layer effects of hydroxychloroquine: a follow up study by sdOCT. Cutan Ocul Toxicol. 2013;32:204–9.
Taban M, Sharma S, Williams DR, Waheed N, Kaiser PK. Comparing retinal thickness measurements using automated fast macular thickness map versus six-radial line scans with manual measurements. Ophthalmology. 2009;116:964–70.
Heussen FM, Ouyang Y, McDonnel EC, Narala R, Ruiz-Garcia H, Walsh AC, et al. Comparison of manually corrected retinal thickness measurements from multiple spectral-domain optical coherence tomography instruments. Br J Ophthalmol. 2012;96:380–5.
Gokmen O, Yesilirmak N, Akman A, Gür Güngör S, Yücel AE, Yeşil H, et al. Corneal, scleral, choroidal and foveal thickness in patients with Rheumatoid arthritis. Turk J Ophthalmol. 2017;47:315–9.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
The authors declare that they have no conflict of interest.
Additional information
Publisher’s note: Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
About this article
Cite this article
Cakir, A., Ozturan, Ş.G., Yildiz, D. et al. Evaluation of photoreceptor outer segment length in hydroxychloroquine users. Eye 33, 1321–1326 (2019). https://doi.org/10.1038/s41433-019-0425-z
Received:
Revised:
Accepted:
Published:
Version of record:
Issue date:
DOI: https://doi.org/10.1038/s41433-019-0425-z
This article is cited by
-
Is optical coherence tomography angiography a useful tool in the screening of hydroxychloroquine retinopathy?
International Ophthalmology (2021)


