Abstract
Background/objectives
To investigate changes in corneal endothelial cell density (CECD) after initial Ex-PRESS surgery in Japanese patients with open-angle glaucoma (OAG) followed-up for 36 months.
Subjects/methods
Corneal specular microscopy was used to examine preoperative and postoperative (3, 6, 12, 24 and 36 months) CECD and CECD changes were analysed. Kaplan–Meier survival curve was used to examine CECD maintained at 95% level, and Cox proportional hazards model was used to detect the risk factors for CECD loss. Intraocular pressure (IOP) changes during the course were also examined.
Results
A total of 79 eyes of 79 patients (standalone surgery, 24 cases; combined cataract surgery, 55 cases) were investigated. Preoperative CECD (mean ± SD) was 2521 ± 305 cells/mm² and 2429 ± 366 (P = 0.003, adjusted for Bonferroni correction), 2462 ± 332 (P = 0.002), 2457 ± 317 (P < 0.001), 2433 ± 333 (P < 0.001), and 2387 ± 352 (P < 0.001) at 3, 6, 12, 24 and 36 months, respectively. The decrease rate was calculated as 1.8%/year. Further, 95% maintenance CECD at 36 months was 50.0% (95% confidence interval, 37.1–63.0%). Both univariate and multivariate Cox proportional hazard models showed that a low preoperative CECD was a significant risk factor for CECD loss. Baseline IOP of 19.3 ± 5.8 mmHg decreased at all measurement points (P < 0.001) after surgery.
Conclusion
CECD after initial Ex-PRESS surgery in 36 months might not be clinically problematic. However, longer-term follow-up is necessary, and regular CECD measurement should be performed, especially in patients with low CECD.
Similar content being viewed by others
Log in or create a free account to read this content
Gain free access to this article, as well as selected content from this journal and more on nature.com
or
References
Weinreb RN, Aung T, Medeiros FA. The pathophysiology and treatment of glaucoma: a review. Jama. 2014;311:1901–11.
Nakazawa T, Fukuchi T. What is glaucomatous optic neuropathy? Jpn J Ophthalmol. 2020;64:243–9.
Noauthors. The effectiveness of intraocular pressure reduction in the treatment of normal-tension glaucoma. Collaborative Normal-Tension Glaucoma Study Group. Am J Ophthalmol. 1998;126:498–505.
Heijl A, Leske MC, Bengtsson B, Hyman L, Bengtsson B, Hussein M. Reduction of intraocular pressure and glaucoma progression: results from the Early Manifest Glaucoma Trial. Arch Ophthalmol. 2002;120:1268–79.
Arora KS, Robin AL, Corcoran KJ, Corcoran SL, Ramulu PY. Use of various glaucoma surgeries and procedures in medicare beneficiaries from 1994 to 2012. Ophthalmology. 2015;122:1615–24.
Traverso CE, De Feo F, Messas-Kaplan A, Denis P, Levartovsky S, Sellem E, et al. Long term effect on IOP of a stainless steel glaucoma drainage implant (Ex-PRESS) in combined surgery with phacoemulsification. Br J Ophthalmol. 2005;89:425–9.
Netland PA, Sarkisian SR Jr., Moster MR, Ahmed II, Condon G, Salim S, et al. Randomized, prospective, comparative trial of EX-PRESS glaucoma filtration device versus trabeculectomy (XVT study). Am J Ophthalmol. 2014;157:433–40. e433
Shaarawy T, Goldberg I, Fechtner R. EX-PRESS glaucoma filtration device: Review of clinical experience and comparison with trabeculectomy. Surv Ophthalmol. 2015;60:327–45.
Mariotti C, Dahan E, Nicolai M, Levitz L, Bouee S. Long-term outcomes and risk factors for failure with the EX-press glaucoma drainage device. Eye (Lond). 2014;28:1–8.
Shimazaki J, Amano S, Uno T, Maeda N, Yokoi N. National survey on bullous keratopathy in Japan. Cornea. 2007;26:274–8.
Ishida K, Moroto N, Murata K, Yamamoto T. Effect of glaucoma implant surgery on intraocular pressure reduction, flare count, anterior chamber depth, and corneal endothelium in primary open-angle glaucoma. Jpn J Ophthalmol. 2017;61:334–46.
Aihara M, Kuwayama Y, Miyata K, Ohtani S, Ideta R, Hashimoto Y, et al. Twelve-month efficacy and safety of glaucoma filtration device for surgery in patients with normal-tension glaucoma. Jpn J Ophthalmol. 2019;63:402–9.
Casini G, Loiudice P, Pellegrini M, Sframeli AT, Martinelli P, Passani A, et al. Trabeculectomy versus EX-PRESS shunt versus ahmed valve implant: short-term effects on corneal endothelial cells. Am J Ophthalmol. 2015;160:1185–90. e1181
Omatsu S, Hirooka K, Nitta E, Ukegawa K. Changes in corneal endothelial cells after trabeculectomy and EX-PRESS shunt: 2-year follow-up. BMC Ophthalmol. 2018;18:243.
Wagschal LD, Trope GE, Jinapriya D, Jin YP, Buys YM. Prospective randomized study comparing Ex-PRESS to trabeculectomy: 1-year results. J Glaucoma. 2015;24:624–9.
Arimura S, Miyake S, Iwasaki K, Gozawa M, Matsumura T, Takamura Y, et al. Randomised clinical trial for postoperative complications after Ex-PRESS implantation versus trabeculectomy with 2-year follow-up. Sci Rep. 2018;8:16168.
Miyake K, Matsuda M, Inaba M. Corneal endothelial changes in pseudoexfoliation syndrome. Am J Ophthalmol. 1989;108:49–52.
Wang M, Sun W, Ying L, Dong XG. Corneal endothelial cell density and morphology in Chinese patients with pseudoexfoliation syndrome. Int J Ophthalmol. 2012;5:186–9.
Higashide T, Nishino T, Sakaguchi K, Yamada Y, Sugiyama K. Determinants of corneal endothelial cell loss after trabeculectomy with mitomycin C. J Glaucoma. 2019;28:61–67.
Cnaan A, Laird NM, Slasor P. Using the general linear mixed model to analyse unbalanced repeated measures and longitudinal data. Stat Med. 1997;16:2349–80.
Bourne WM, Nelson LR, Hodge DO. Central corneal endothelial cell changes over a ten-year period. Invest Ophthalmol Vis Sci. 1997;38:779–82.
Mietz H, Roters S, Krieglstein GK. Bullous keratopathy as a complication of trabeculectomy with mitomycin C. Graefes Arch Clin Exp Ophthalmol. 2005;243:1284–7.
Mohammadpour M, Jabbarvand M, Javadi MA. Focal corneal decompensation after filtering surgery with mitomycin C. Cornea. 2007;26:1285–7.
Rao GN, Shaw EL, Arthur EJ, Aquavella JV. Endothelial cell morphology and corneal deturgescence. Ann Ophthalmol. 1979;11:885–99.
Rosado-Adames N, Afshari NA. The changing fate of the corneal endothelium in cataract surgery. Curr Opin Ophthalmol. 2012;23:3–6.
Sato M, Sakata C, Yabe M, Oshika T. Soft-shell technique using Viscoat and Healon 5: a prospective, randomized comparison between a dispersive-viscoadaptive and a dispersive-cohesive soft-shell technique. Acta Ophthalmol. 2008;86:65–70.
Demir AG, Olgun A, Guven D, Demir M, Sendul SY, Akarsu Acar OP, et al. The effect of combined phacotrabeculectomy, trabeculectomy and phacoemulsification on the corneal endothelium in the early stage: a preliminary study. Int Ophthalmol. 2019;39:2121–8.
Freidl KB, Moster MR. ExPRESS shunt surgery: preferred glaucoma surgery in residency training? Surv Ophthalmol. 2012;57:372–5.
Hau S, Bunce C, Barton K. Corneal endothelial cell loss after baerveldt glaucoma implant surgery. Ophthalmol Glaucoma. 2021;4:20–31.
Zhang Q, Liu Y, Thanapaisal S, Oatts J, Luo Y, Ying GS, et al. The effect of tube location on corneal endothelial cells in patients with ahmed glaucoma valve. Ophthalmology. 2021;128:218–26.
Tan AN, Webers CA, Berendschot TT, de Brabander J, de Witte PM, Nuijts RM, et al. Corneal endothelial cell loss after Baerveldt glaucoma drainage device implantation in the anterior chamber. Acta Ophthalmol. 2017;95:91–96.
Acknowledgements
The authors would like to thank Enago (www.enago.jp) for the English language review.
Funding
Supported in part by the GRANT 18K16945 from the Ministry of Education, Culture, Sports, Science and Technology of Japan (R.S.). The funding organization had no role in the design or conduct of this research.
Author information
Authors and Affiliations
Contributions
Study conception and design: MA and SS; Acquisition of data: YA, RS, TF, MH, SS and MA; Analysis of interpretation of data: YA, RS and MA; Drafting of the manuscript: YA, RS and MA; Critical revision: MH, SS and MA.
Corresponding author
Ethics declarations
Competing interests
The authors declare no competing interests.
Additional information
Publisher’s note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
About this article
Cite this article
Aoyama, Y., Sakata, R., Fujishiro, T. et al. Changes in corneal endothelial cell density after initial Ex-PRESS drainage device implantation and its relating factors over 3 years. Eye 37, 69–74 (2023). https://doi.org/10.1038/s41433-021-01888-1
Received:
Revised:
Accepted:
Published:
Issue date:
DOI: https://doi.org/10.1038/s41433-021-01888-1
This article is cited by
-
Short-term efficacy and safety of PreserFlo MicroShunt in Japanese patients with medically treated primary open-angle glaucoma
Japanese Journal of Ophthalmology (2025)
-
Comparison of corneal endothelial cell density reduction between primary open-angle glaucoma and pseudo-exfoliation glaucoma patients at 3 years after Ex-Press® surgery
International Ophthalmology (2024)
-
Corneal endothelial cell loss after EX-PRESS surgery depends on site of insertion, cornea or trabecular meshwork
International Ophthalmology (2023)