Abstract
Background
To investigate the morphologic features of iris in the highly myopic (HM) eyes using a novel swept-source optical coherence tomography (SS-OCT).
Methods
In this retrospective case-control study, 100 eyes of 100 patients scheduled to have cataract surgery were included, categorized into the control (22 mm< AL < 24.5 mm) and HM (AL ≥ 26 mm) groups. Iris volume (IV), area of anterior iris surface (IS), area of posterior IS, and average iris thickness (IT), as well as anterior chamber volume (ACV) and trabecular-iris space at 500 µm (TISA 500) were evaluated using SS-OCT. The associated factors with morphologic features of iris were also investigated.
Results
The HM group showed significantly larger IV and area of anterior and posterior IS than the control group (all P < 0.001), while no difference was identified in IT between the groups. Similar trend in IV was seen in the superior and nasal segments, and area of anterior and posterior IS showed similar trends in all segments except the temporal segment. The IV, area of anterior and posterior IS were all positively correlated with AL (all P < 0.001). Multivariate linear regression revealed that a larger IV was associated with greater ACV. Both larger areas of anterior IS and posterior IS were associated with male, longer AL, greater ACV, and smaller TISA 500.
Conclusions
The HM eyes showed larger IV and area of IS than the control eyes, indicating a coronal expansion of the iris with AL. Iris morphology correlated with anterior chamber angle configuration.
This is a preview of subscription content, access via your institution
Access options
Subscribe to this journal
Receive 18 print issues and online access
$259.00 per year
only $14.39 per issue
Buy this article
- Purchase on SpringerLink
- Instant access to full article PDF
Prices may be subject to local taxes which are calculated during checkout



Similar content being viewed by others

Data availability
The data supporting the findings of this study are not publicly accessible due to privacy concerns and can be available from the corresponding author upon reasonable request.
References
Chong EW, Mehta JS. High myopia and cataract surgery. Curr Opin Ophthalmol. 2016;27:45–50.
Hoang QV, Chan X, Zhu X, Zhou X, Shentu X, Lu Y. Editorial: Advances in Management and Treatment of High Myopia and Its Complications. Front Med (Lausanne). 2022;9:846540.
Chatziralli IP, Peponis V, Parikakis E, Maniatea A, Patsea E, Mitropoulos P. Risk factors for intraoperative floppy iris syndrome: a prospective study. Eye. 2016;30:1039–44.
Wu Z, He T, Su Z, Liu Y, He J, Huo Y. A Modified Technique for Preventing Lens-Iris Diaphragm Retropulsion Syndrome in Vitrectomized Eyes during Phacoemulsification. J Pers Med. 2023;13:418.
Xuan Y, Chang Q, Zhang Y, Ye X, Liu W, Li L, et al. Clinical observation of choroidal osteoma using swept-source optical coherence tomography and optical coherence tomography angiography. Appl Sci. 2022;12:4472.
Mak H, Xu G, Leung CK. Imaging the iris with swept-source optical coherence tomography: relationship between iris volume and primary angle closure. Ophthalmology. 2013;120:2517–24.
Jin P, Li M, He X, Lu L, Zhu J, Chang TC, et al. Anterior-Chamber Angle and Axial Length Measurements in Normal Chinese Children. J Glaucoma. 2016;25:692–7.
Cheung CY, Liu S, Weinreb RN, Liu J, Li H, Leung DY, et al. Dynamic analysis of iris configuration with anterior segment optical coherence tomography. Investig Ophthalmol Vis Sci. 2010;51:4040–6.
Holden BA, Fricke TR, Wilson DA, Jong M, Naidoo KS, Sankaridurg P, et al. Global Prevalence of Myopia and High Myopia and Temporal Trends from 2000 through 2050. Ophthalmology. 2016;123:1036–42.
Meng J, Han X, Wang W, Gong X, Li W, Xiong K, et al. Analysis of Iris volume using swept-source optical coherence tomography in patients with type 2 diabetes mellitus. Acta Ophthalmol. 2022;100:e553–e9.
Zhu X, Zhang K, He W, Yang J, Sun X, Jiang C, et al. Proinflammatory status in the aqueous humor of high myopic cataract eyes. Exp Eye Res. 2016;142:13–8.
Tun TA, Baskaran M, Perera SA, Chan AS, Cheng CY, Htoon HM, et al. Sectoral variations of iridocorneal angle width and iris volume in Chinese Singaporeans: a swept-source optical coherence tomography study. Graefes Arch Clin Exp Ophthalmol. 2014;252:1127–32.
Invernizzi A, Giardini P, Cigada M, Viola F, Staurenghi G. Three-Dimensional Morphometric Analysis of the Iris by Swept-Source Anterior Segment Optical Coherence Tomography in a Caucasian Population. Invest Ophthalmol Vis Sci. 2015;56:4796–801.
Wei L, He W, Meng J, Qian D, Lu Y, Zhu X. Evaluation of the White-to-White Distance in 39,986 Chinese Cataractous Eyes. Investig Ophthalmol Vis Sci. 2021;62:7.
Qi J, He W, Lu Q, Zhang K, Lu Y, Zhu X. Schlemm Canal and Trabecular Meshwork Features in Highly Myopic Eyes With Early Intraocular Pressure Elevation After Cataract Surgery. Am J Ophthalmol. 2020;216:193–200.
Meng J, Wei L, He W, Qi J, Lu Y, Zhu X. Lens thickness and associated ocular biometric factors among cataract patients in Shanghai. Eye Vis. 2021;8:22.
Zhu X, Du Y, Li D, Xu J, Wu Q, He W, et al. Aberrant TGF-β1 signaling activation by MAF underlies pathological lens growth in high myopia. Nat Commun. 2021;12:2102.
Ghosh S, Best K, Steel DH. Lens-iris diaphragm retropulsion syndrome during phacoemulsification in vitrectomized eyes. J Cataract Refract Surg. 2013;39:1852–8.
Aptel F, Denis P. Optical coherence tomography quantitative analysis of iris volume changes after pharmacologic mydriasis. Ophthalmology. 2010;117:3–10.
Acknowledgements
We express our sincere gratitude to all the team members and staff who contributed to this study but are not listed as authors. Their generous grants have been crucial in the advancement of our work.
Funding
This article was supported by research grants from the National Natural Science Foundation of China (82122017, 82271069, 81870642, 82371040, 81970780, 81470613, 81670835 and 82301188), Science and Technology Innovation Action Plan of Shanghai Science and Technology Commission (23Y11909800 and 21S31904900), Clinical Research Plan of Shanghai Shenkang Hospital Development Center (SHDC12020111), Shanghai Municipal Key Clinical Specialty Programn (shslczdzk01901). Outstanding Youth Medical Talents of Shanghai “Rising Stars of Medical Talents” Youth Development Program (20244Z00150).
Author information
Authors and Affiliations
Contributions
XZ revised the manuscript, obtained funding, and supervised the process. Yanwen Fang revised the manuscript and supervised the process. CK, JM and LW collected, analysed the patient data and wrote the manuscript. CC and YC collected the patient data and assisted in drafting the manuscript. WH and KZ read and revised the manuscript. YL obtained funding, read and revised the manuscript. CK, JM and LW contributed equally to this work. All authors approved the manuscript and this submission.
Corresponding authors
Ethics declarations
Competing interests
The authors declare no competing interests.
Additional information
Publisher’s note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Supplementary information
41433_2024_3321_MOESM2_ESM.tif
Schematic diagram for the measurement of anterior chamber angle configuration by swept-source optical coherence tomography.
Rights and permissions
Springer Nature or its licensor (e.g. a society or other partner) holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law.
About this article
Cite this article
Kang, C., Meng, J., Wang, L. et al. Morphologic features of iris in highly myopic eyes based on a novel swept-source optical coherence tomography. Eye 38, 3443–3449 (2024). https://doi.org/10.1038/s41433-024-03321-9
Received:
Revised:
Accepted:
Published:
Issue date:
DOI: https://doi.org/10.1038/s41433-024-03321-9