Table 2 Size and speed of the fastest-moving HRCs in each AOO image series, with suspected location and underlying AMD changes on OCT.
Patient number | Eye | Mobile HRC diameter (μm) | Time between images (min) | Speed (µm/s) | Retinal location | Lesion type |
---|---|---|---|---|---|---|
4 | Right | 9 | 49 | 0.0054 | RPE | iRORA |
5 | Right | 13.4 | 115 | 0.0044 | RPE | cRORA |
5 | Right | 17.9 | 110 | 0.0044 | RPE | cRORA |
5 | Right | 17 | 108 | 0.0068 | RPE | cRORA |
6 | Left | 9.8 | 86 | 0.0055 | RPE | cRORA |
7 | Left | 8.8 | 151 | 0.0078 | RPE | cRORA |
8 | Right | 15.7 | 72 | 0.0146 | RPE | large drusen |
10 | Right | 7.9 | 92 | 0.0075 | IZ | medium drusen |
11 | Right | 19.1 | 118 | 0.0022 | RPE | cRORA |
11 | Left | 14.1 | 136 | 0.0101 | RPE | cRORA |
11 | Left | 20.8 | 137 | 0.0008 | RPE | cRORA |
11 | Left | 14.6 | 131 | 0.0098 | RPE | cRORA |
12 | Right | 15.7 | 94 | 0.0029 | RPE | cRORA |
12 | Right | 12.7 | 101 | 0.0068 | IZ | cRORA |